Observer

Admin Guide 7.2


Copyright © 2015, Volicon Inc., All Rights Reserved


Warranty and Limitations

“The information in this document is subject to change without notice and does not represent a commitment on the part of Volicon Inc.; it’s not a binding contract. Volicon Inc. will not be held responsible for failures or errors in the text of the document. Nor be liable for it to any claim from any third party. Documentation is provided “as is.” All conditions, representations and warranties, expressed or implied, including any implied warranty of merchantability, fitness for a particular purpose or non-infringement, are disclaimed, except to the extent that such disclaimers are held to be legally invalid. This document contains proprietary information belonging to Volicon Inc. Such information is supplied solely for assisting properly authorized users of Volicon Inc. systems. No part of its contents may be used for any other purpose, disclosed to any person or firm. No part or parts of this document shall be copied, used for commercial purposes or passed to any third party for any use, without approval Volicon Inc. The text and graphics are for the purpose of illustration and reference only. The information herein is subject to change without notice”


Document Details


Document Name:

Admin Guide 7.2

Part Number

AG-7.2.B1-012815

Related Software Versions

7.2.2


Contents

  1. Introduction 1

    1. Purpose and scope 1

    2. About the Observer 1

    3. Conventions used in the manual 3

  2. Observer Servers 4

    1. Dimensions and Power Requirements 4

    2. Mounting, Power, Basic Connections 5

      1. Power Distribution 5

      2. Total Power 5

      3. HVAC 5

      4. STB Shelves 5

      5. Typical Rack Layout with Set Top Boxes 6

    3. Server Front Panel Indicators and Controls 7

      1. Power ON, Shutdown 7

      2. Observer Front Panel Indicators 8

      3. Drive Carrier Indicators 10

    4. Observer Enterprise Chassis Video Connections 10

  3. Network Configuration 12

    3.0 Security Considerations 12

    3.0.1 Firewall Configuration for Observer Encoder Servers 12

  4. Initial Setup 13

    1. Supported Operating Systems 13

      1. Central Server Installations 13

      2. Probe Installations 13

      3. PC Client Installations 13

    2. Browser Support 13

      1. Chrome, Firefox, and Safari Support 14

      2. Internet Explorer Support 16

  1. Exploring the Maintenance Tree 17

    1. Settings 17

      1. Observer Versions 17

      2. Session Timeout 19

      3. System Date Format 19

      4. Global Keyword Alert Limits 19

      5. Default Login Settings 20

      6. Miscellaneous Settings 20

      7. Server Host and Web Server IP 21

      8. Content Export Module Settings 22

      9. Content Matching Module (CMM) Settings 23

      10. Expired Data Cleanup 23

      11. Login Page Control 24

      12. Expired License Information 25

      13. Password Policy 25

      14. Dashboard Channels Order 26

      15. Favorites 26

      16. SNMP Receivers 27

      17. Fault Email Alerts 28

      18. Secure Login 28

      19. Audio Black List 28

    2. User Account Management 29

      1. Create a New Group 30

      2. Edit Group 32

      3. Display Users 33

      4. Add a New User 33

      5. Edit User Account 34

      6. Forgotten Passphrase 34

    3. Event Viewer 35

      1. Accessing the Event Viewer 35

      2. Active Users 35

      3. Import Data 36

      4. Import Profiles 38

    4. Alerts 38

      1. Setting Up the Fault Email Server 38

      2. Setting Up Alert Notifications 39

      3. Adding and Editing Alerts 40

    5. Alert Template 42

  1. Central Configuration 43

    1. Encoders 43

      1. Encoder Page Fields 44

      2. Groups 45

      3. Probes 46

      4. Managing Probe Server 47

      5. Delete Probe 51

      6. Encoder Details 52

      7. Sub-Encoders 55

      8. Loudness Monitoring 55

    2. Software Updates 58

      1. Uploading New Software 58

      2. Probe Software Update 59

    3. Task Manager 60

  1. Programs 61

    1. Manual Program Input Process 62

    2. As-Run Files Program Input Process 62

    3. Exporting Program Clips 63

  1. Ratings 64

  2. Observer/RPM Alerting 67

    1. Definition of Key Terms 67

    2. Color Coded Frame 68

      1. Red: Video Alert 69

      2. Yellow: Audio Alert 69

      3. Blue: Other Alerts 70

    3. Encoder Stream Alerting 70

      1. Media Faults 70

      2. Alert and Trap Generation 70

    4. Equipment and Link Alerts 70

      1. Equipment and Link Alerts Table 70

    5. System alerts 71

      1. System alerts table 71

      2. Media Faults with Examples table 72

  1. Nielsen Audio Video Encoding (NAVE) feature description 78

    10.1.1 NAVE Configuration 79

  2. SNMP Notification 81

    1. MIB variables 81

      1. MIB variables table 81

      2. MIB variables alert example table 83

      3. SNMP notification signaling table 84

      4. System alerts 85

      5. Configure Notification 86

  1. Capture Cards and Breakout Cables 89

    1. Compatible Capture cards 89

    2. BLACKMAGIC INTENSITY PRO 90

    3. Osprey460e card 91

      1. Audio breakout 9 pin Mini-Din Pin-out 92

      2. Composite Video Interconnect diagram 92

  1. SDI-SD/HD System Interconnect 93

    1. SDI-SD/HD Interface diagram 93

      1. Observer Enterprise Chassis SDI Connections 94

    2. Blackmagic Decklink SDI 95

      1. Decklink SDI Coax Connector Diagram 95

      2. Dolby Digital 5.1 Support 96

      3. Decklink SDI Channel features 96

    3. Blackmagic Decklink Quad SDI–SD/HD 96

      1. Decklink Quad SDI–SD/HD Connector Diagram 97

      2. Breakout Cable BNC to Mini BNC Adapter 97

    4. Decklink Duo SDI/HD adapter interface 98

    5. Transport stream DeckTec interface 99

      1. Dektec DTA-2160 99

  1. General Interconnect Description 100

        1. Media SD Video/ Audio and HDMI Interconnections 100

        2. IR Transmitter Interconnections 101

  2. NTP Time Server Configuration 102

        1. Selecting a Time Server 102

        2. Setting Poll Interval 103

  3. What NOT to do on the server side 104

  4. RAID Alert Notification 105

    1. RAID Variants 105

      17.0.1 RAID 1 105

      17.0.2 RAID 5 105

      17.0.3 RAID 6 105

    2. RAID Controllers 106

    3. 3Ware Configuration on Observer Servers 106

    4. RAID Maintenance 108

    5. Hard Disk Drive (HDD) Replacement 109

    6. Hard Drive Outage 109

  1. Antivirus Excluded Storage Areas 110

  2. Active Directory (AD) Integration 111

    1. Prerequisites 111

    2. AD Operation 111

    3. Troubleshooting 112

  1. Troubleshooting and Maintenance 113

    1. No Video Playing 113

    2. Internet Explorer Issues Due to Skype Add-ons 113

    3. Exporting Video Clips 113

      20.2.1 Client Machine Not Working 113

    4. Install Player CAB File 114

    5. How to Remove Volicon Media Player from a Client PC 114

    6. License Problem Sources 114

    7. Support Portal 115

  1. System Monitoring Procedure 116

    1. Checking the Encoder Status 116

      1. Probe Fault 117

      2. Monitor Media Streams 117

      3. Encoder Fault 117

      4. Encoder fault corrective actions 118

      5. Checking Memory and CPU Utilization 118

      6. Windows Task Manager 118

    2. Checking Video Storage Utilization 119

  1. Appendix A Using Osprey to Examine A/V Streams 121

    22.0 Adjusting Audio with Osprey Config 123

  2. Appendix B Revision History 125

    1. Observer releases 125

    2. Revision change history 126


1 INTRODUCTION


    1. Purpose and scope

      Welcome to the Volicon Observer Admin Guide. This document will provide the details and instructions necessary to guide you through the configuration and operation of the Volicon Observer platform. It addresses specific system and network administrator functions in the Volicon environment, including setting up:

      • Inputs from video networks

      • Encoders

      • IP networks

      • Alerting thresholds

      • User and user accounts

      • Other system related parameters in the Observer.

        It is also useful for advanced users to gain further understanding of the system.


    2. About the Observer

      The Observer™ is a powerful tool for automated media monitoring, logging, and quality assurance with applications for broadcast and related networks:

      • Automated monitoring and diagnosis of multichannel broadcasts

      • Standards-based loudness monitoring

      • Media logging and related features

        The Observer environment is typically composed of a Central Server (CS) and a group of probe servers often spread out between your network management location, your operations centers and unmanned remote distribution points. This composition gives you complete visibility into the content deployed on your network.

        Observer has the ability to log content from multiple video sources in the post production, transmission, delivery, and reception video distribution chain. You can log content at any stage of the video production or delivery process: The amount of content you can log is limited only by your storage space.

        It is the only product on the market that logs video content down to the individual frame level, at the same standard frame rate as the source. In



        addition, Observer allows you to log content from many different input types such as HD/SD-SDI, ASI, IP, DVB-(S, S2, T, T2), 8VSB, Clear QAM, Component, Composite, S-Video, and HDMI. .


        image

        Figure: Observer Functional Diagram

        The Observer ingests the video and audio. Next it takes the original stream content and transcodes it to a lower resolution and bit rate for storage on the Observer Server, essentially making a copy of the original source also known as a Low Bit Rate Proxy (LBRP). The LBRP is stored locally on the server and then streamed to each end user as an individual stream, which allows multiple users to access the same content without adversely affecting other users on the Volicon solution. There are several reasons for creating a low bit rate proxy of all incoming video content:

      • It allows multiple users to access the Volicon solution simultaneously

      • It minimizes impact on network resources

      • It allows the Observer to store content on each server for much longer periods of time

        Observer works with networks of all sizes. The system is preconfigured with default settings so that small installations can work right out of the box. For larger installations, you can define as many probe servers and their streams in the Central Server as you need to completely monitor your network.


    3. Conventions used in the manual


      Type

      Classification

      Boldface

      Denote names and labels in the Graphical User Interface (GUI)

      Capitalization

      Denotes key words module names, components and signal labels

      <Boldface>

      Denotes push buttons and other similar user input devices

      @Hyperlink

      Automatic links to other sections in the document, denoted by boldface and the “@” prefix


  1. OBSERVER SERVERS

Volicon offers a number of different servers to meet customer requirements. Servers are rack mounted and come in 1U – 4U heights. Most servers have dual redundant 50/60Hz power supplies. Server includes chassis slides and power cords.


image

Figure: Typical Observer Server (SC835TQ-R800BK)


    1. Dimensions and Power Requirements


      Server

      Storage Capacity

      Power Requirements


      All supplies 50/60Hz

      Height is multiple of 1U, (1.74 inch,

      44.45 mm)

      Weight

      SC512C 200B

      1 bay

      Single 200W 100-240V 4-2A

      1U x 14.0” (346mm)

      deep

      12.8lbs (6.8kg)

      SC815TQ 563UBK

      4 RAID bays

      1 aux bay

      Redundant Supplies 700W 100-140V 8.5-6A

      750W 180-240V 5-3.8A

      per supply

      1U x 25.6” (650mm)

      deep

      36 lbs (16.3kg

      SC825TQ

      563UBK

      8 RAID bays

      1 aux bay

      Single 560W supply

      100-240V 7.7A max

      2U x 25.5” (648mm)

      50lbs

      SC825TQ R700BK

      8 RAID bays

      1 aux bay

      Redundant 700W Supplies 100-240V 10-4A per supply

      2U x 25.5” (648mm)

      deep

      52lbs (23.6kb)

      SC835TQ

      R800BK

      8 RAID bays

      4 aux bays

      Redundant 800W Supplies

      100-240V 10-4A per supply

      3U x 25.5” (648mm)

      deep

      72lbs

      (32.7kb)

      SC836A

      R1200BK

      16 RAID bays

      2 aux bays

      Redundant 800W Supplies

      100-240V 10-4A per supply

      3U x 25.5” (648mm)

      deep

      72 lbs

      (32.7kb)

      SC846A R1200BK

      24 RAID bays

      2 aux bays

      Redundant 900W Supplies 100-240V 4.5-11A per

      supply

      4U x 26.0” (660mm)

      deep

      75lbs (34.0kg)

      Table: Observer Server Space and Power requirements


    2. Mounting, Power, Basic Connections

      Servers mount in standard 19-inch racks. Follow your rack manufacturer’s mounting instructions for safe and stable mounting. If the server power supply has a 110/240 switch, make sure to set it to the proper voltage 120/240VAC, 50/60 Hz.

      Plan for your rack space and cooling requirements by creating a table similar to the one shown above. List your servers, set top boxes and related equipment. If possible include a PC or laptop dedicated for use with the Observer servers.

      Attach a dedicated display, keyboard and mouse so that during urgent service there is no delay in logging into the server. See the Observer Site Prep Guide for more details.

      Attach LAN and video cables as needed.


      1. Power Distribution

        Servers should preferably be on dedicated circuits so that if one trips, it will not affect more than one power supply module per server.

        We recommend connecting the Observer system to a UPS or a similar high availability power supply.


      2. Total Power

        Add the power requirements of all other onsite equipment to obtain total system power consumption.


      3. HVAC

        Ensure your HVAC has sufficient cooling capacity to handle the total power (Watts) of heat dissipated by the servers and your other onsite equipment.


      4. STB Shelves

        If you use Set Top Boxes (STBs), we recommend mounting these in 19 inch racks (482.6 mm) for solid installation and good IR shielding. Locate the shelves close to the Observer server to reduce cable lengths. As an example see the STB shelf shown below. It fits in a 19 inch rack 2U high.


        image


        Figure: Set Top Box Mounting Shelf


      5. Typical Rack Layout with Set Top Boxes

        This section describes rack layout and interconnections in scenarios when Set Top Boxes (STBs) are used.


        image


        Figure: Typical STB Rack



        • Note: a maximum of two HD streams should be used per Observer Encoder server chassis as shown above


          image


    3. Server Front Panel Indicators and Controls

      For security purposes a locking front cover prevents access to drive bays, auxiliary drives and the power and reset buttons. With the security panel installed only the system level status LEDs are visible.

      Note: there may be minor differences in Panel Indicators depending on the specific server and configuration.


      image

      Figure: Typical Server Indicators and Controls (Security Panel Removed)


      1. Power ON, Shutdown

        To power up the server remove the locking front panel security cover and press the Power switch.



        After powering up the Observer server, wait for the login screen to appear. If you are logging into the system for the first time, consult the “Read Me First” guide or contact the Volicon support team. Observer runs as a service (configured by default) and does not require a user/admin log in to operate.

        To shut down Observer, from the console use the <Start><Shutdown> sequence. To restart the server, use the <Start><Restart> menu. Do not unplug the power cord or press the Reset button so as not to impact the database. (Its re-indexing might require help from the Volicon support group). If for some reason the main Windows server console screen is not accessible, use the front panel <Power> button to do an orderly Windows shutdown of the server.

        Pressing the <Reset> button forces the CPU to reset, the same as if power had been cycled.


      2. Observer Front Panel Indicators

        There are several LED indicators on the control panel and others on the drive carriers to keep you informed of overall system status and the activity and health of specific components. This section explains the meanings of the LED indicators and the appropriate responses.



        image

        Figure: Observer Front Panel Indicators (Security Panel in Place)



        Indicators:


        image

        • Power Failure: When this LED flashes, it indicates one of the power supplies has failed.


          image

        • Alert: This LED is illuminated when an alert condition occurs. See the table below for details.


          Alert Status

          Description

          Constant red

          An overheat condition has occurred. (This may be caused by cable congestion)

          Blinking red (1Hz)

          Fan failure, check for an inoperative fan.

          Blinking red (0.25Hz)

          Power failure, check for a non-operational power supply

          Constant blue

          Local UID has been activated. Use this function to locate the server in a rack mount environment.

          Blinking blue

          Remote UID is on. Use this function to identify the server from a remote location.



          image

        • NIC2: Indicates network activity on LAN2 when flashing

        • NIC1: Indicates network activity on LAN1 when flashing


          image


        • HDD: Indicates IDE channel activity. SAS/SATA drive and/or DVD-ROM drive activity when flashing.


          image

        • Power: Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system is operating.


      3. Drive Carrier Indicators

        Each drive carrier has two status LEDs. They are normally hidden behind the security panel. Remove the panel to access the drive bays.

        Blue: Drive activity. Flashes when drive is accessed

        Red: Drive Failure


    4. Observer Enterprise Chassis Video Connections

      All video input connections on the Observer Enterprise Chassis are located on the back panel.


      IPMI RJ-45

      USB Main Network

      image

      RJ-45

      Video input on capture card 2

      Video input on capture card 1


  1. NETWORK CONFIGURATION

Volicon recommends that you assign a static IP address to each Observer server. If you are relying on a public network (such as the Internet) for connecting your various server deployments, additional considerations apply.


    1. Security Considerations

      If you are using the Internet for your connections, place firewalls both between your Observer Encoder servers and their Internet connection, and between your Central/Web server and its Internet connection.


      1. Firewall Configuration for Observer Encoder Servers

        On the firewall protecting your Observer Encoder servers, you must open:

        • TCP Ports 4504/5502 for content streaming (to client PCs). Port 4504 allows A/V streaming.

        • TCP Port 3306 for database updates. Open Database Connectivity (ODBC), a standard programming language middleware API for accessing Database Management Systems, uses TCP port 3306.

        • Port 8080 for Mobile device streaming

        • Port TCP 3389 or a VPN connection for support

          Central/Web server:

        • Ports TCP 80 for the HTTP (Web frontend and client PCs)

        • Port TCP 25 SMTP for Hmailserver outgoing email alerts

        • Port 943 and 4504 for Silverlight

          Be sure to provide sufficient bandwidth between server and the monitoring facility. Size the bandwidth to provide 1.2-1.5 times the sum of the viewed stream’s bandwidth, with a minimum connection speed of 10 Mbps

          See the Observer Site Prep Guide for details.


  1. INITIAL SETUP


    1. Supported Operating Systems


      1. Central Server Installations

        The Observer Central Server can be installed on a computer running any of the following operating systems:

        • Windows 2003

        • Windows 2008 x64 and x32

        • Windows 7 x64

        • Windows 2012


      2. Probe Installations

        Probes can be installed on computers running any of the following operating systems:

        • Windows 2003

        • Windows 2008 x64

        • Windows 7 x64


      3. PC Client Installations

        You can install the PC client on computers running the following operating systems:

        • Windows 7

        • Windows XP (for basic monitoring)


    2. Browser Support

      The Observer supports four interface browsers:

      • Internet Explorer

      • Chrome

      • Firefox

      • Safari



      Internet Explorer uses the PC client; Chrome, Firefox, and Safari provide you a clientless user interface.

      To enable clientless mode, please contact Volicon support

      Please read the Clientless configuration documentation for complete details.


      1. Chrome, Firefox, and Safari Support

        The Observer supports Chrome, Firefox, and Safari through a clientless user interface. Note that the Observer only supports Safari on the MAC OS; Safari on Windows is not supported.

        The clientless user interface provides you with a simplified control bar, which is compensated for by a set of keyboard shortcuts.


        image

        Figure: Clientless User Interface

        Prior to using the clientless interface, the stored video and audio content must be converted to H264 video and AAC audio formats. Please contact Volicon support to enable the clientless feature. The Silverlight plugin used with this interface is usually installed automatically on the client PC. If not, install it manually.

        The keyboard shortcuts for the clientless user interface are given in the table below. You can also use these shortcuts to complement Multi-view monitoring, and to enhance your player control in general.


        Key

        Function

        L

        Live

        P

        Picture in Picture

        S

        Split Screen

        F

        Full Screen

        M

        Mute/unmutes

        D

        Switch between main and expanded display

        Z

        Fast reverse

        X

        Normal reverse

        C

        Slow reverse

        <Spacebar>

        Pause/play

        V

        Slow forward

        B

        Normal forward

        N

        Fast forward

        I

        Image snapshot

        <Cursor up/down>

        Volume up/down

        Mouse scroll <up/down>

        Single frame forward/backward

        <’>

        Cut clip <Mark in/Markout>


      2. Internet Explorer Support

        The Observer supports the following versions of Internet Explorer in both 32 and 64 bits:

        • IE9

        • IE10

        • IE11 (in Compatibility mode)

          The IE player has the following advantages over the clientless interface:

        • Media export

        • Frame by frame display

        • Clips preview (Bookmarks and Fault clip thumbnails)

        • Split screen and Picture-In-Picture display modes

        • Display of all metadata


  1. EXPLORING THE MAINTENANCE TREE

The Maintenance Tab has several sub categories which generally apply to the entire ecosystem of the Observer solution. Sub Categories include:

  1. Settings

  2. User Management 3.Event Viewer 4.Import Data 5.Event Viewer 6.Alerts

7.Alert Template


    1. Settings

      Expand <Maintenance>→<Settings> to display Settings. Settings are global in nature, and apply to all end users and the modules configured on the system.


      1. Observer Versions

        When you access the Volicon Observer, you can see your software versions at the upper left:


        image

        Figure: Observer Maintenance


        • Minimum Player Version

        • Installed Player

        • Frontend Version

        • Product Version

          Depending on the installed options, the following module versions may also be listed:

        • Producer Version

        • CMM

        • CMM Client

“Minimum Player Version” – The minimum client version required for the frontend, web client PCs to work with this release of Observer.

“Product Version” - the backend portion of the Observer software.


        1. Version Interoperability

          Due to a new protocol in 7.2 QB1, the central server, probes, and player software need to have the same release version and build numbers.


        2. Upgrade Considerations

          A system running Observer version 6.2 or higher can be upgraded to version 7.2. However, for earlier versions (such as 6.1, 6.0, or 5.6), please consult our Support department.


      1. Session Timeout

        The Session Timeout defines how long an inactive web client can be connected to the Observer. The Observer will log the user off when this timer expires. To disable the timeout, set it to zero.


        image

        Figure: Session Timeout


      2. System Date Format

        The date format which is displayed throughout the Observer media player can be configured to display the appropriate regional format. Observer provides a drop- down list from which you can select the correct system date format.


        image

        Figure: System Date Format


      3. Global Keyword Alert Limits

        The Global Keyword Alert Limits option allows you to:


        • Force use of rate limiting – enabling (checkbox) to limit the frequency of alerts

        • Minimum time between alerts – limits alert frequency to selected period (minutes/hours/days)


        image

        Figure: Global Keyword Alert Limits


      4. Default Login Settings

        This setting allows the administrator to prepopulate the username and password. This allows all end users the ability to login into the Observer without entering a username / password combination.

        • Volicon recommends that you do not enable this feature.


        image


      5. Miscellaneous Settings

        In your role as administrator, you may import program information for the Observer in the form of “as-run files” or ratings files. The Observer system can automatically ingest and process these files by implementing a "Hot Folder". The Hot Folder resides on the Central server and any files imported or copied into the Hot Folder directory will be automatically processed and incorporated into program or ratings data displayed in the Observer Media Player.


        1. Hot Folders

          The Hot Folders Location sets the directory location of the hot folder located in the Central Server. This setting should not be changed from the default of C:/Hotfolder.


          image


          Figure: Miscellaneous Settings Hot Folder


          Clicking the <Update> button next to the Hot Folder location creates a C:\HotFolder directory on the server with subfolders using the names of each channels displayed on the Home tab of the Observer Media Player. The software automatically imports the As-run logs from these folders. See @Hot Folders in the “As-Run files” section later in this document.


      6. Server Host and Web Server IP

        Observer can display clips referred to by embedded links (such as those located in email messages) if those clips are reachable from the Internet/LAN. To do so, the Observer system needs to know the (Central) “Server hostname” (if NAT is used) and the “Web server IP” address (of the central server) to render the clips on the client PCs. The “Server Hostname” must be valid and reachable from the outside world.

        You can specify both the Server host and the Web server IP either with explicit IP Addresses or with valid DNS names.


        image

        Figure: Miscellaneous Settings Server IP


        Click the <Update> button to save your changes.


      7. Content Export Module Settings

        The Content Export Module is an integrated application which runs on a separate server than the Observer. It is used for automating the export of recorded content on a scheduled or recurring basis. It is also used to export content for non-Internet Explorer based media players such as a MAC environment. Typical scenario includes broadcast station XXXX wants to archive or export the three daily local news broadcasts every day. Simply create a job in the Content Export Application which will automatically export three time slots to network attached drive every day. Another function allows end users to repurpose media content. It lets you leverage broadcast assets in the new media world where one program can be delivered to multiple portals: broadcast, web clips, over-the-top TV and mobile video. The Content Export/CMM modules can be configured under Maintenance> Settings.


        image

        Figure: Export Settings


        Hovering over the “?” icons provides tool tips to help you configure the various fields/text boxes. Set your CEM parameters according to the table below:


        Server URL

        Content export server host name/IP address

        Server HTTP port

        Default HTTP port of content export services

        Download publisher status

        Availability of the download publisher module

        Table: CEM Settings

        Click the <Update> button to save your changes. See the Content Export manual for more details. The default server HTTP port is 405.


      8. Content Matching Module (CMM) Settings

        CMM, an optional module, is for organizations that need to be notified when certain audio/visual assets are broadcast. Similar to the Content Export Module, CMM runs on a separate server than the Observer. Fully integrated with the Observer, the CMM is easy to set up and can either operate in stand-alone mode, or in integration with other systems. To open the CMM window, go to

        <Maintenance>→<Settings>→ click on <CMM Settings> to expand.


        image

        Figure: CMM Settings Window

        Set your CMM parameters according to the table below:


        Server Host

        CMM server host name/IP address

        Server HTTP port

        Default port of Content matching services

        Table: CMM Settings

        Click the <Update> button to save your changes. See the Content Matching manual for more details.


      9. Expired Data Cleanup

        The Observer ecosystem has daily processes in place to clean up expired data without any user intervention. In the event any expired clips, closed captions, or other data is missed during these the processes, you can manually remove expired data in the Expired Data Cleanup panel, located at Maintenance> Settings >Expired Data Cleanup.


        image

        Figure: Expired Data Cleanup

        You can remove the following kinds of data:

        • Events

        • Remove license expiration message

        • Channels

          • Closed Captions

          • Ratings

          • Programs

          • Clips (Including GPI)

        Select the items you wish to remove and click <Cleanup>. This clears the expired data immediately. From this window you can also set your CC Retention period. This field determines how long Observer stores the Closed Captions and Teletext on the system.


      10. Login Page Control

        This page allows administrators to disable user access during maintenance or upgrade periods. You can also display a message to end users describing the type and duration of the maintenance. Clicking the <OFF> radio button will disable the ability for any user to login to the Observer Media Player. It does not kick currently logged in users off the system.


        image


        Figure: User Login Control


      11. Expired License Information

        This page provides a quick way to verify expired software licenses.

        • Note: This page only refers to Volicon licensed software, not Microsoft or other third parties.


        image


        image

        Figure: Expired License Warning


      12. Password Policy

        Enabling this option requires uses to periodically reset passphrase and use a combination characters to create strong passwords. The system will refuse to accept a passphrase change if it does not meet the requirements and will prompt you with those requirements. The criterion for password acceptance is:

        1. Minimum of eight characters

        2. One Upper case letter

        3. One lower case letter

        4. One number

        5. One symbol character

        6. NO REPEATING characters



        Simply click the check box and click on <Update>


        image

        Figure: User Password Policy


      13. Dashboard Channels Order

        You can determine whether all end users see your programs/channels displayed in the dashboard on the Home page in order by “Channel name” or by “Channel order index” under Maintenance>Settings> Dashboard channels order. Sorting by Channel Name will sort the channel listing alphabetically from A-Z. Sorting by Channel Order Index will sort the channel listing based on the time each channel was originally configured into the Volicon Observer.


        image

        Figure: Dashboard Channels Order


      14. Favorites

        When the “Favorites” feature is disabled (the default), the channels shown in the Dashboard will be based on the permissions for each end user set by the admin Dashboard. Enabling Favorites allows the end user to pick and choose which channels are visible in the dashboard. If a new channel(s) is added to the system, end users must go into the favorites section to add it their view.


        image

        Figure: Favorites


      15. SNMP Receivers

        The Observer system sends SNMP traps to customer servers, usually to “Network Management Systems” (NMS). Complete information on the Observer’s use of SNMP is available @10.

        To define and edit the SNMP trap destination:

        • Click the <SNMP Receivers> line to expand it.

        • Click the <Add> label (top left of the SNMP Receivers location) to define a new SNMP trap - a popup window will appear:


        image

        Figure: Add New SNMP Receiver Window

        Populate the window using the information in the table below.


        Protocol

        Enter the version your receiver is using. The RPM system supports SNMP v1 and SNMP v2

        Community

        Password to establish connectivity with the SNMP receiver. This is public by default (unrestricted access).

        Host

        Name or IP of destination where the trap is to be sent.

        Port

        Enter the port used for SNMP traffic with the host. By default, this is port 162.

        Add

        Add groups that appear in the Active directory.


        Groups

        Lists the groups.

        Table: SNMP Receiver Settings

        Click <OK> to save the newly-created SNMP trap destination and return to the Settings menu. You should see your new SNMP receiver in the list. To edit a SNMP destination in the list, click the “Edit” (pencil) icon; to delete it click the red “X” icon.


      16. Fault Email Alerts

        Specify the email account name Observer uses as the from email address when sending alerts under Maintenance>Settings>Fault Email Alerts.


        image

        Figure: Alert Email from Address


      17. Secure Login

        This setting along with several other internal configurations enables the Observer Media player to use HTTPS, a secure encrypted connection, instead of HTTP. This is not to be changed by any admin, please contact Volicon support to enable this feature.


        image

        Figure: Secure Login


      18. Audio Black List

        This setting allows admins to block specific audio tracks from being selected by end users. If a channel has three audio tracks but the end users can only have access to #1 & #2, the admin can add the 3rd audio track here and it will not be displayed in the "audio tracks" section of the advanced menu on the Home Page of the Observer Media Player.


        image


        Figure: Audio Black List


    1. User Account Management

      If more than one person will be using the Observer, you may wish to set up varying access levels for those individuals. The User Management Interface is a flexible tool for controlling user and group access to the Observer system. It allows the Volicon Administrator to create permission based "Groups" then create/add end users to each group based on the tasks allowed for each individual. Every action on the Volicon system is tied to a permission. As an admin you can create as many groups and end users as you wish, but any individual can associated with only one permission group

      Access User Management through the Web client interface (see Observer User Manual for the login).

      Select <Maintenance>→<Users> from the left menu.


      image



      Figure: User Management

      A user added to the <Administrators> group will have full privileges and full access to all video content. Volicon recommends that you create additional groups with selected privileges for regular users. The <Create a new group> button is located above the group list, The <Edit group>, <Delete group> and

      <Add new user> icons are located next to group names as shown in the figure above.

      • Administrator group access privileges are preconfigured and cannot be changed or deleted.


      image


      1. Create a New Group

        To add a new group, click the <Create a new group> button at the top of the page. The Add Group window will open.


        image

        Figure: Create New Group Screen


        Group Permissions

        View users

        View users but not modify their configuration

        Manage users

        Add / edit user/ group names and their access.

        Require View users to be selected

        Create/View/Edit/Delete

        clips

        Manipulate clips

        Export clips/Export TS

        content

        From Observer to a Client PC. TS content exports full

        bandwidth data content

        View Fault Clips

        Ability to View Fault Clips

        Add/Delete/Edit programs

        Ability to Add/Delete/Edit programs based on the import of As Run log data in the Programs Tab

        Manage channels

        Configure encoder-channels

        Create CC Alerts

        Ability to create Closed Caption alert

        Import data

        Ability to Import data such as stamps

        View ratings

        Ability to View ratings (assuming the feature/option is available on the system)

        Manage Content Export


        Manage Content Export

        Profile

        Manage Content Export Profile

        View/Delete GPI clips

        Access Clips GPI Clips

        View CMM

        Ability to view CMM (assuming the option is available)

        Manage CMM

        Ability to manage CMM (assuming the option is

        available)

        Unlimited play session

        Playback without timing out

        Program Loudness Report

        Access Reports Program Loudness

        SW Updates

        Update Observer Central Config SW Update

        Task Manager

        Access Central Config Task Manager

        Settings

        Access Maintenance Settings

        Event Viewer

        Access Maintenance Event Viewer

        Audio Whitelist


        Table: Group Permission Settings


      2. Edit Group

        To Edit a group move the cursor to the desired group, hover over the <Edit Group icon> to the right of the <Add new User> button and left click. This will open the edit group window. This is the same window as the new group with relevant group options selected. Press <Update> at the bottom to save changes.



        See the table in @Error! Reference source not found. for the definitions of each option.


      3. Display Users

        Clicking the down/up arrow to the right of the group name reveals the users associated with that group. Clicking the arrow again returns you to the previous screen. Here new users can be added or the existing users edited or deleted. See

        <Add new user>, <Edit User>, <Delete User> buttons in figure below. The

        <Delete user> button permanently deletes a user. Checking the <Disable box> temporarily prevents that user from logging in without the need to delete the account.


      4. Add a New User

        Any user added to any group will inherit the permissions of that group. To add a new user to a group, click the <Add New User> button.

        Add the User name, Password and select the streams of interest in the “Access to video” section.

        The Concurrent Video field sets how many video players can be open at a time. The default is unlimited; use to pulldown to constrain the number of players the user is able to run simultaneously.

        Press the <Add> button to save the modifications.


        image

        Figure: User Management


      5. Edit User Account

        To edit an existing user, expand the group to show users associated with that group. Click the <Edit User icon>. The Edit User window will open, and will provide you with the same options as the Add User window. The edit user feature allows you can change access to video channels and recover from forgotten passwords.


      6. Forgotten Passphrase

        A common administrator tasks will be assisting users who have forgotten their passphrase. Once created, the plaintext passphrase is no longer visible. If a user indicates they have forgotten their passphrase access their account and use the

        <Edit> feature to create a new one for them.



        If strong password policy <Maintenance>→<Setting>→<Password policy> is enabled be sure the new passphrase meets the requirements or the system will refuse to accept the new passphrase.


    2. Event Viewer


      1. Accessing the Event Viewer

        The Event Viewer, available at <Maintenance>→<Event Viewer> from the Left menu, allows you to view a running log of events and the currently-logged-in users on the Observer system.

        Click the <Event Viewer> tab to display the event log. The Event Viewer logs nearly every event any end user does on the system. It is an audit tool for admins to make sure no one is misusing the Observer system.


        image

        Figure: Maintenance/Event Viewer


      2. Active Users

        Click the <Active users> tab to display a list of the currently-logged-in users and their session expiration times. The trashcan icon in the Force Quit column is used to forcefully terminate a session, although this could cause loss of unsaved items.


        image


        Figure: Active Users


      3. Import Data


        1. As-Run Files Input Process

          Searchable program guides allow you to organize and find video based on program name, channel and time. In your role as administrator, you typically set up the program information for the Observer in the form of “as-run files”. As-run files contain the program scheduling information, which is converted to video clips stored in the Observer system.

          • Note: this is an optional application and requires the customer to purchase the appropriate license.


            image


        2. Manually Import Data

          Note: Observer supports the Daily-Ratings report. Prior to importing this data into Observer you need to convert it to a Text (Tab-delimited) format.

          Note: Your import ability may be restricted by your administrator and thus may not be available.


          image


          Figure: Maintenance/Import Data

          To import data:

          1. After file conversion to a supported format, click Maintenance Import Data. Use the <Browse> button to locate the saved file. As an alternative you can type the information directly it the text box below.

          2. Press the <Next> button to open the Channel and time zone dialog box.

          3. Select the desired Channel and Time Zone

          4. Press the <Do Import> button to save changes.


          Once the import succeeds, you can start importing another file with the <Next Import> button. You can also go to the Programs page to view the video.

          To generate the Rating graph, in Ratings choose the same Date and Time range as the imported file. Click the <Ratings> button to display the graph; see the Ratings section @8 below.


        3. Hot Folders

          Observer automatically imports the as-run files periodically from a Hot Folder location located on the Central Server. It is configured in Maintenance Settings Hot Folder.


          image

          Figure: Maintenance/Miscellaneous Settings


          Clicking the <Update> button next to the Hot Folder location creates a C:\HotFolder directory on the server with subfolders using the display names of each encoder channel. It is the responsibility of the customer administrator to deliver updated as-run and rating files to these directories.

          There is an automated Windows Task which runs periodically to automatically import specific file types for Ratings or As Run Log. The software automatically looks for the appropriate As-run log and/or Ratings data file types within these folders


      4. Import Profiles

        You can create an Import Profile to compensate for the video delay when you import. Open Maintenance Import Profiles in the Web client and set the time zone and Delay Offset for the encoder channels to compensate for video delay between the desired time and when the actual Observer video was loaded to storage. This compensation results in accurate timing of Programs related to the As-Run files.


    3. Alerts


      1. Setting Up the Fault Email Server

        In order for your users to receive fault alerts, you must specify the email address you have assigned the Observer. To do so, under Maintenance>Settings>Fault Email Alerts enter the Observer’s e-mail address.


        image


        Figure: Fault Email Alerts Email Address


      2. Setting Up Alert Notifications

        Observer enables you to specify email address to receive alert notification and which alerts to send each respondent. Alerts can be tailored by alert type and channel for each respondent so they only receive alerts of interest. Users can receive the following types of alerts:

        • Video

        • Audio

        • CC/TT

        • Media Hub

        Select Maintenance>Alerts to view summary page. This displays a list of email recipients and which event classes they are subscribed.


        image

        Figure: Maintenance>Alerts


      3. Adding and Editing Alerts

        To add a new user click the <Add E-mail> box or to edit an existing subscriber click the <pencil> icon to the right of their e-mail address.


        image

        Figure: Adding a New User

        The top of the alert box allows you to select which classes of alert get sent to the recipient. The Channels section below that specify channels the user will receive alerts so they are not inundated with unwanted email.


        image

        Figure: Add e-mail alert Window

        Click <Save> to update changes.

        The <Delivery Test> button allows you to test the recipient was configured correctly.


        image


        Figure: Alert Email Configuration


    4. Alert Template

      This page allows the admin to customize the format of the alert emails which, if configured, are sent to all configured recipients. Admins can customize the header and body of the email.


      image

      Figure: Alert Template


  1. CENTRAL CONFIGURATION


    1. Encoders

      The Observer ecosystem is organized in a hierarchal manner. There are several different layers which make up the entire system: Groups, Probes, and encoders. Access probe groups, probes and encoders at Central Config> Encoders.

      • Group(s) - created by your Volicon administrator; it is a means to associate multiple Observer probes under one unified heading. Groups can be created by input source, geography, network capture location, etc...

      • Probe(s) - each server, as a whole unit, contains anywhere from one to 16 video, audio, and metadata capturing inputs. It stores all the recorded content locally and streams out the recorded content to end users.

      • Encoder(s) - is the High or Low bit rate proxy copy created for each item of video content recorded on the system. In the case of the Observer, it is a direct one-to-one relationship of each physical video input on the probe to the proxy stored on the Probe. In the case of the Observer TS, it is the individual channels logged inside each MPTS or SPTS.

      • A probe server contains one or more encoder-streams or channels.

You must assign each probe server in the system to a probe group. Use groups to help you organize your streams and manage alerts, since a probe group often shares a geographical territory or a specific service area.



image


Figure: Probe Architecture


      1. Encoder Page Fields

        Access your probe groups, probes and encoders-streams at Central Config

        Encoders.

        From this page you can configure groups (e.g., US-COLO HD) probes (e.g., Demo- 3HD), and encoders (e.g., DEMOHD1, DEMOHD2, DEMOHD3).


        image

        Figure: Probe groups, probes and encoders


        Settings View

        The <Settings View> tab displays full information about Groups, Probes and Encoders. In order to edit any of the selections you must be in <Settings View>.

        Dashboard View

        <Dashboard View> is a simplified display of only Group and

        Encoder name.

        Search

        For large installations using the search feature speeds up access to desired probe or encoder and suppresses non matching fields.

        Add Group

        Used to add a new Group. A group is a collection of associated Probes.

        Add Probe

        Physical server with 1-16 capture channels.


        Update Profile

        Pushes changes out to Probes

        Expand All

        In expanded view encoders are shown in relationship to their associated Probe.

        Collapse All

        In collapsed view Probes are displayed and encoders suppressed.

        Edit Columns

        The Encoder page displays various encoder settings. Use the check box to select which fields to display.

        Expand/collapse field

        Click the arrow to the left of each Group and Encoder to expand the field click again to collapse.

        Probe/Encoder Status Indicator

        To the left of each is a status indicator, red is down green indicates operational.

        Table: Encoder Page Fields


      2. Groups


        1. Creating Groups

          A Group is simply a label use to associate multiple Probes. The first step is to create the Group name.

          In either <Settings View> or <Dashboard View> click the <Add Group> button. Enter the name of the Group you wish to create then press <Add>. The new group will be populated on the encoder page. The new group is flagged in red since there are no associated Probes.


          image


          Figure: Add Group


        2. Deleting a Group

          If a Group is no longer needed hover over the Group name and press the

          <Delete> button. A warning message will pop up asking if you are sure. Deleting a Group has no effect on the underlying Probes it simply removes the named association.


      3. Probes


        1. Add Probe

          To add a probe to the system, click the <Add Probe> button. The Add Probe Window will open.



          image


          image


          Figure: Add Probe

          Type in the “IP Address” of a probe of interest and select a “Group” from its dropdown box to associate these together. Observer automatically extracts the probe’s name and encoder information from the probe server.


      4. Managing Probe Server

        Hovering over the desired Probe displays three buttons: <License> <Edit Probe> and <Delete> to the right of the name. Make your changes and click the <Update Profiles> button to save your work.



        image

        Figure: Probe Information


        1. Probe Licenses

          Press <License> to display information about installed software components.


          image

          Figure: Update License Window

          The Update License window provides you with the information listed in the table below.

          To update your license, enter the Event ID and the Event Data you received from Volicon, and click <Update>.


          Probe License

          License


          Status

          Green if valid license; Red if unlicensed

          Expiration

          Demo licenses expire, other licenses are permanent

          Computer ID

          Reflects License Event ID from most recent software update

          Code Entry

          Reflects License Event Data from most recent software update

          HD channel limit

          Maximum # of monitoring channels – counts toward Total Channel Limit

          TS Channel Limit

          Maximum # of transport streams – counts toward Total Channel Limit

          Total Channel Limit

          Absolute # of monitoring channels

          Long Term Storage

          Storage option not subject to automatic purge

          CC Enable

          Closed Caption monitoring

          AC3

          Maximum # of AC3 audio channels

          AFD/WSS

          Active Format Description (AFD) and Widescreen Signaling (WSS).

          Extra Audio Stream


          Loudness Measurement

          Maximum # of loudness measurements

          NAVE:

          Nielsen Audio Video Encoder logging option

          Number of encoder with detectors:


          Interactive Services

          Scripting module for Interactive Services

          Owner

          Licensee contact info

          Update License


          The Update License entries at the bottom of the page are used to add optional software components. This information is provided when Probe is licensed or optional modules are added

          • Event ID

          • Event Data


        2. Probe Details

          To see details on a specific Probe, hover over the Probe name and press the

          <Edit> button to open and display probe details as shown below.


          image

          Figure: Edit Probe Details


          Details on each field are provided in the table below.


          Probe Status

          Green, Probe us accessible, Red Probe is not responding

          Encoder Number

          Number of Encoder channels installed on Probe

          Probe Name

          This name is extracted from the probe server during probe

          creation (see section “Add Probe” @ 6.0.3.1)

          Group

          Group name is selected from the preconfigured groups

          using a dropdown box

          SW Version

          (Probe SW Upgrade)

          Displays probe’s current software version. In addition, it is used to upgrade the probe by selecting a higher probe version from its dropdown list.

          LAN IP

          Address within the LAN to reach the probe

          LAN Port

          LAN TCP port of the streaming server (default is 4504) - insure it is open on route from probe to the client PC, i.e., routers; firewalls are set to permit traffic on that port.

          WAN IP

          WAN address of the Central/web server when a NAT is used. The address is used to facilitate Observer playback through the WAN.

          WAN Port

          TCP port of the streaming server (default is 4504) for the WAN connection- ensure it is open on route from probe to

          the client PC, i.e., routers and firewalls

          Live Streamer Port:

          WAN

          Low latency streaming port (input)

          Live Lag


          Live Streamer Port: LAN


          License

          License type” (i.e. Demo) and “Expiration date

          Machine Info

          Probe additional information: “Memory Usage” – RAM usage “Platform Name” - OS (Windows 7) “Operating System” – 32/64Bit

          CPU Usage” – i.e. 11 “System Memory” - RAM size

          Table: Probe Settings

          To complete the operation, press the <Save Probe> button.


      5. Delete Probe

        When you delete a probe, an “Alert” popup screen will appear - press <Yes> to confirm the deletion of the probe. Deleting a probe deletes it from the Observer Media Player. It does not stop the probe from continuing to capture content or stop any service running on that probe.


        image


        Figure: Alert Window


      6. Encoder Details

        To edit an individual encoder within a specific Probe, hover over the encoder name. An <edit> button will appear to the right. Click on the button or left click on the encoder name itself.


        image


        Figure: Edit Encoder


        image


        Figure: Encoder details Page

        Test the connectivity of the new encoder-stream by pressing the <Test> button. Press the <Save> button to complete the encoder edits.


        Details on each field are described in the table below.


        Status Indicator

        Media stream status such as running. It is also stopped, also reflected by color. The color of Encoder-stream status such as RED - Running, Stopped, is also reflected

        by the status icon color.

        Encoder Name

        Name of an encoder (usually four on a probe); set up

        with a Probe Manager

        Display Name

        Frontend, friendly name for the encoder/channel

        Probe Name

        Inherited from the Probe server Encoder is attached

        Color

        Helps users to distinguish between the encoder- channels; user configurable property, also used in

        graphing colors

        Expires After

        Define period for keeping video and CC data

        CC adjustment

        Time adjustment for CC, usually left at the default

        value

        Amplification

        Adjustment of audio level within the Observer system. It’s better to adjust the signal outside the probe before

        it gets to the probe server.

        CMM Monitoring

        Enable optional content matching for this encoder

        Video Settings

        Input Feed” - i.e., TS, SD (read only, not configurable from GUI)

        TS Program” – Transport Stream selected channel (read only, not configurable from GUI) “Resolution” – capture and streaming output resolution, i.e., 640x360

        Bitrate” - – capture and streaming output bit rate

        In bits per second, i.e., 1000000 bps

        Sub Encoder

        Create additional video encoder, typically configured

        for lower bit rate

        Audio Settings

        Loudness Meter” (Enable checkbox), - See “Loudness

        Monitoring”, an optional module

        As-Run Log Settings

        Time Zone offset, sets local time zone offset from UTC

        for time stamping

        Test Button

        Runs test to Insure the frontend connects to the

        encoder and the new configuration is working properly

        Preview Button

        Press to display and preview the input video

        Table: Encoder Stream Configuration


      7. Sub-Encoders

        Each encoder has a primary video codex that creates the channel stream digital multimedia archive. If desired, additional encoders may be configure. Sub- encoders are typically set for lower resolution and bit rate then the primary codex to serve specific monitoring or file exchange requirements.

        Adding sub-encoders have the same server requirements as the identical setting for the primary codex. CPU cycles are needed for the compression engine an disk storage for the resulting file.


      8. Loudness Monitoring

        With the optional loudness module enabled, the Observer and Observer TS systems perform loudness meter measurements to meet the following standards: EBU R 128, BS-1770-1, BS-1770-3, ATSC A/85 and EBU Tech 3341/2/3.

        Volicon's loudness module is accurate per each frame of video and takes a measurement every 100 milliseconds. Measurements can be done with or without gating windows (-10 dB but adjustable) over:


        • Momentary( M) - is an average over 400ms

        • Short term (S) - is an average over 3s

        • Short Form integrated are measurements which are two minutes or shorter. There are a total 7 user defined, configurable measurements - e.g. 10s, 30s, 60s…). By default Volicon sets the short term values as follows: 10, 15, 20, 30, 60, 120, 0.

        • Long Form Integrated measurements greater than two minutes. There are a total of 7 user defined, configurable measurements - e.g. 1 hour, 6 hour, 1 day, 5 day) intervals. By default Volicon sets the long term values as follows: 60, 360, 1440, 0 , 0 , 0, 0.

        • Loudness Range Measurement (LRA) quantifies the variation in a time-varying loudness measurement. Loudness Range is supplementary to the main audio measure, Program Loudness, of EBU R 128. Loudness Range measures the variation of loudness on a macroscopic time-scale, in units of LU (Loudness Units). The computation of Loudness Range is based on a measurement of loudness level as specified in ITU-R BS.1770, albeit with a different gating threshold. Loudness Range should not be confused with other measures of dynamic range..


        For Audio Loudness standards, graphing, data export and Program Loudness Reporting (PLR) details see the Observer User Manual, “Loudness Monitoring” section.


        image

        Figure: Loudness Configuration


        1. Loudness Configuration

          To configure the basic loudness parameters, go to <Central Config>

          <Encoders>. Click on an encoder to edit its loudness parameters. Click the

          <Loudness Enabled> checkbox. This expands the Loudness section.

          • Very important: the loudness license must be enabled on the probe. Activating Loudness without the proper license for all configured audios per channel could result in disabling the capturing and encoding process.


            image



            For Loudness configuration parameter details see the table below. Complete your choices, and click <Save> to push your configuration to the encoder.



            Loudness measurement enable

            Enables loudness metering for all configured audios on this specific channel

            Gating Mode (pulldown)

            Complies with the ATSC 2011, ATSC 2013 and EBU

            standard for gating loudness measurements; enabled either in frontend and backend, see figures above

            Enable LRA

            Loudness Range Average quantifies the time-varying loudness measurements. LRA is the lowest peak to highest peak change over each configured time interval. For more details on LRA see the “Observer User Manual”

            section “Programme Loudness Range LRA”.

            Enable True Peak

            Enables monitoring the value of the audio signal waveform of a program in the continuous time domain; detects peak loudnesses that otherwise would escape

            the sampling process.

            AC-3 properties

            Processed with loudness range algorithm

            Pre DialNorm Calculation

            DialNorm indicates the level of average spoken dialogue within the encoded audio program.

            Typical values for short and long term are factory preset. DialNorm should be enabled whenever an encoder is

            ingesting a digital audio stream such as optical, s/pdif, or Dolby AC-3

            Short IPL (Sec)

            Short Integrated Results

            7 defined sampling durations (usually left at the default values). The durations can be graphed - see Observer

            User Manual 6.2 section “Audio loudness graphing

            parameters”.

            Long IPL (Min)

            Long Integrated Results

            7 defined sampling durations (usually left at the default values). The durations can be graphed - see Observer

            User Manual 6.2 section “Audio loudness graphing

            parameters.

            Input Adjustment

            If measurements are being made without dial norm and not using the EBU standard, this value can compensate for the difference in measurements from dial norm value. This setting is usually enabled when making measurements from a Set Top Box which does not pass

            dial norm data.


            Program Save Period:

            These measurements may be saved for the same time set of other Encoder setting or explicitly set to a

            different amount of time.

            Table: Loudness configuration


    1. Software Updates

      Periodically, Volicon releases new software for the Observer. The upgrade process is managed in conjunction with Volicon support.

      Volicon Support will email you the Software Release Installer(s), with a file name of ProbeSetup ####.msi. Download the software and save it to a directory on your local or available network storage.


      1. Uploading New Software

        Once you receive the latest software, an authorized Admin can upload the installer(s) on the Central server. To do so:

        • Go to <Central Config> <SW Updates>.

        • Browse to the new installer. The Observer will verify the installer you choose.

        • Once the installer is verified, the <Upload Installer> button activates.

        • Click <Upload Installer>. The Central server will make the release available for all probes.


        • Note: This action makes the new software available, but does not automatically update any probes at this point.


        image


        image


        Figure: Software Update


        If multiple software releases have been saved Central Config displays them in an ordered list with the most current revision at the top.


        Press the <Trash Can> icon to delete unneeded old revisions.


      2. Probe Software Update

        When you are ready to upgrade a probe, go to <Central Config> → <Encoders> and hover over the desired probe. Access the pulldown labeled SW Version to select a higher software version. Press the <Save Probe> button at the bottom of the page to commence the update process. When the update finishes a status message is displayed at the top of the page.

        • During the update process the Probe service is stopped and then automatically comes back on line when the update completes. This will result in a short loss of captured content for up to two minutes.


        image


        image


        Figure: Probe Software Update Procedure


    2. Task Manager

      This page displays the status of scheduled tasks. In the <Actions> column at the extreme right of the page are icons that let you manually select the task to run and enable/disable automatic dispatch.

      • Note: stopping ANY process could have a negative impact on the Observer System. Do NOT stop or start any Tasks without previously conferring with a Volicon Support team member.


      image


      image

      Figure: Task Manager


  1. PROGRAMS

The Programs screen allows you to organize video recordings based on program name, channel name and time. There are two methods to create program based content:

  • Manually set up Observer programs

  • Use “As-run files” integration to skip manual data entry and integrate with an existing automation system. Users can look up logged content according to program name, media ID, or other data from the as-run log. Automatic importation of common as-run logs simplifies finding content for ad verification and compliance purposes.

You can also search for video footage of interest based on program search parameters.

Select <Programs> from the left menu to reach the Programs screen.


image

Figure: Programs with loudness measurements

At the top of the page are search options to speed up locating the desired program. Use the Time Range Defined period” instead of “anytime” to search between the “From” and “To” times. In addition to the “Program Name”, you can filter for an A/V stream with the “Channel” drop down box option, or leave it open with the “Any Channel” option, see above.

At the bottom of the page is a page count and <Forward> and <Back> buttons.



To watch a program clip hover over the desired program name and left click to open the program viewer.

At the far left of each program are <Edit> and <Delete> icons. The <edit> icon allows you to rename the clip and change its associated date and time.

To delete a program clip use the <trashcan> icon; a warning message asks you to confirm the operation.

As with other Observer pages The <Show/Hide column> menu allows you to customize the display.


    1. Manual Program Input Process

      To manually add a program press the <Add Program> button. This opens a small dialog box.


      image

      Figure: Manual Add Program

      Enter a descriptive name for the clip in the <Program Name> field and select the program channel from pulldown. Use the calendar function to specify the date and time of the clip. Default clip length is one minute, increase or decrease length as desired. If you intend to use the captured program as a CMM Stamp be sure it is at least 5 seconds long.

      Click the <add> button, the program clip be automatically be added to the program list.


    2. As-Run Files Program Input Process

      Searchable program guides allow you to organize and find video based on program name, channel and time. In your role as administrator, you typically set up the program information for the Observer in the form of “as-run files”. As-run files contain the program scheduling information, which is converted to video clips stored in the Observer system.



      • Note: this is an optional application and requires the customer to purchase the appropriate license.


        image


    3. Exporting Program Clips

      Once a program clip has been created use one of the export functions to export the clip. If the particular Export function is “greyed out” it indicates the optional software needed to perform the function has not been installed.


  1. RATINGS

    Note: Ratings is an optional module which may not be available to all users. Your access may be limited by your administrator. Volicon does not supply your ratings data. The customer must provide the ratings data; the Observer supports multiple rating sources.

    While viewing video programs, the ratings module facilitates efficient comparison of broadcasts at specific times and for selected channels. This feature does not work in real time. Most data imported into the system is at least 24 hours old. We support different time spans of data including minute-by- minute. To see ratings, click the “Ratings” icon on the player control-bar. (See the Observer User Manual for more details.)


    image

    Figure: Ratings Example

    The “Demographic Type” for ratings can be selected from a corresponding drop down window. These profile the human population characteristics for the selected geographical areas where the ratings are sampled:


    image


    Figure: Maintenance/Import Data


    Some example demographic groups include:

    • HOUSEHOLDS Profile the average Households

    • P12-17, P18-24 Populations between ages of 12 and 17 and 18 and 24

    • F18-24 Female population between ages of 18 and 24

    • M50+ Male population over the age of 50 The following “Chart Types” can be selected:

    • Rating: provides the raw rating data, describing what percentage of

      households watched the feed

    • Gain Loss: provides the change in ratings over the given time period

    • Cumulative: provides the cumulative ratings data

    For instruction on how to import Daily Ratings data, see the “Import Data” section above. Matching color markings are used to link rating graphs to the corresponding video displays. The graph color to channel key is located to the right of the graph as shown below.

    You can select your timescale granularity on the top right of the graph.


    image


    Figure: Timescale Granularity


    Use the vertical line to select a specific time on the ratings curves that corresponds to programs shown on the displays. Moving the line will display the correct video for the times traversed.


  2. OBSERVER/RPM ALERTING

Since the Observer RPM system is based on the Observer system, alerting for both products is covered here. The features below that are related to channel or service scanning and apply to the RPM product only.


    1. Definition of Key Terms



      Term

      Definition


      Encoder/stream

      Observer hardware module that receives and processes Media signals from one to four set-top boxes.

      Depending on the context, the encoder is sometimes referred to as an Encoder-stream


      Media Fault

      When the incoming media: video, audio and metadata crosses defined level and duration threshold limits for normal operating conditions


      Channel/Service

      Network’s media service content as perceived by the end user. Typically a cable or broadcast channel or a specialty service.


      Alert

      A notification of a media fault generated when an encoder detects a fault. In addition to storing a video clip, if enabled the system issues email notification and a SNMP trap of the event


      Trap

      A message sent to an external system after detecting an alert and enabled with the channel notification control, usually referring to a SNMP alert

      Table: Observer/RPM Alerting Key Terms


    2. Color Coded Frame

      The Observer conveys encoder and stream faults to users by color coding the player frame surrounding player displays. This coding reflects the live, real-time alert status of the encoders even during playback of stored media.

      Color coded frame for encoders is enabled in the Preferences (Web) page.

      The green (OK), red (video) yellow (audio) blue (other) alert is a colored box superimposed over the outer margin of the video image. Note the image below contains a video alert in the lower right, and an Other alert in the upper right.


      image

      Figure: Video and Other Alerts


      Turn on alerts in the Preferences menu.


      image

      Figure: Show Alerts Frame Checkbox


      1. Red: Video Alert

        The Observer identifies a video alert with a red frame around its channel display. Red alert is the highest priority; it takes precedence over other lower priority alerts when detected simultaneously.

        • Static video (no movement)

        • Black video (solid black screen)

        • Lost video (i.e. disconnected feed)


      2. Yellow: Audio Alert

        The Observer identifies an audio alert with a yellow frame around its channel display. The audio alert display takes precedence over lower priority alerts (Blue) when detected simultaneously.

        • Low audio level

        • High audio level


      3. Blue: Other Alerts

        The Observer identifies lowest priority alert level with a blue frame around its channel display.

        • Dial error

        • Script error

        • Other


    3. Encoder Stream Alerting


      1. Media Faults

        Media faults such as “Black Screen” or “Low Audio” are detected in the probe encoder-stream, usually exceed certain characteristic media parameters such as level and duration threshold. See the “Media” section @Error! Reference source not found. for more details. These faults are detected at the probes and forwarded to the CS. The CS captures the corresponding fault clips and also records the related events in the “Event log”.


      2. Alert and Trap Generation

        Configure your thresholds for alerts and traps in the Probe Manager or the Probe Manager. See the “Error! Reference source not found.” section @Error! Reference source not found..

        After a media fault is detected, Observer well cut a fault clip. If you have also enabled notification, Observer will send an SNMP trap and alerting email


    4. Equipment and Link Alerts

      The alerts below generate SNMP traps in addition to fault clips and email alerts. Other alerts related to scanning or STB control apply only to the RPM system.


      1. Equipment and Link Alerts Table


        EQUIPMENT ERROR

        Caused by an internal connection problem within the probe between the Listener and the Probe encoder services. This occurs when the encoder



        service is in the middle of terminating its operation but not yet completely stopped, while the listener is trying to access the encoder during this time.

        NAVE-TS-FAULT

        A watermark with an older Timestamp was received than the Timestamp in the defined reference.

        NAVE-PERC-FAULT

        The percentage of good watermarks against foreign watermarks Source ID (SIDs) is smaller than defined in Error percentage variable.

        NAVE-PERC-WARN

        The percentage of good watermarks against foreign watermarks is between Error percentage and Warning Percentage.

        NAVE-WM-FAULT

        The amount of good received watermarks is smaller than defined in the Minimum Good watermarks variable.

        NAVE-TS- RECOVERY

        A watermark that satisfies the time limitations has just arrived regardless of its SID.

        NAVE-WM- RECOVERY

        The total amount of good watermarks in a certain sliding window satisfies the Minimum good watermarks variable.

        NAVE-PERC- RECOVERY

        The ratio between good watermarks against foreign watermarks is higher than the Warning Percentage.

        Table: Equipment and Links Alerts


    5. System alerts

      Most of the system related alerts are detected at the Probes and forwarded to the CS. The CS generates Event log and Event viewer entries.


      1. System alerts table


        Alert

        Description

        ENCODER STOPPED

        The Encoder module processing a media stream has stopped.


        SERVICE STOPPED

        The Encoder service (operating system routine) has stopped.

        Dial error

        Digit dialing errors have been detected with a custom script written using the Interactive Services (optional) module.

        Script error

        One of two faults has occurred:

        STORAGE ERROR

        A hard disk file error event.

        GPI fault

        This fault can be triggered by any media fault to provide electrical alert to external hardware. This option is usually not used in the RPM.

        POWER

        A toggle "STB Power" event.

        Probe Down Alert

        The Probe is not working.

        LICENSE

        A License expiration event.

        1. The system detected a syntax error in the script

        2. A script has failed due to an IR problem

        Table: System Alerts


      2. Media Faults with Examples table

        The Observer uses three specific terms to establish the parameters of its media fault alerts:

        • Certainty: the level threshold default..

        • Duration: the duration threshold for a fault. .

        • Recovery: the period of time that must pass after a fault ceases before the system is considered to no longer be in a fault.



          Alert Types


          Description of Operation and Examples

          Level, Detection Ranges and Defaults

          AUDIOLOW

          (Low audio)

          Low audio fault is detected when the incoming audio stays below the low level threshold and the duration of the fault exceeds the duration threshold. Disable audio alert detection on channels with frequent silence.

          All these values are defined in the Probe Manager on the Probe. If you wish to change any Certainty, Duration, or Recovery levels, please contact Volicon Support.

          (RPM only) AUDIOLOW Alert Example: Audio alert is configured on a channel. Certainty threshold = -40 dB; Duration set to default of 30 sec. Audio input signal detected = -69 dB (below Certainty ) for 41 sec; thus exceeding the Duration threshold. A media fault therefore is detected, generating an audio alert and automatically creating a fault clip, which is stored under the Clips --- Fault Clips section on the Observer Media Player.

          When notification is enabled, SNMP trap and email messages are sent if configured by the admin.

          Certainty: -40 dB Level threshold -

          increase for noisy lines,

          e.g., -35 dB

          Duration: 30 sec

          Recovery duration default: 10 sec


          AUDIOHIGH

          (High audio)

          Audio high fault is detected when the incoming audio stays above the high level threshold for sufficient duration to exceed the audio duration threshold.

          AUDIOHIGH Alert Example: Audio alert is configured on a channel. Certainty threshold = - 1 dB; Duration set to default of 30 sec. Audio input signal detected = 2 dB (above Certainty) for 6 minutes (exceeding the cycle time for the lineup plus the Duration threshold). A media fault therefore is detected, generating an audio alert and automatically creating a fault clip, which is stored under the Clips --- Fault Clips section on the Observer Media Player.

          When notification is enabled, SNMP trap and email messages are sent if configured by the admin.

          Certainty: -1 dB

          Duration: 30 sec

          Recovery duration default: 10 sec

          AUDIO-OK

          Audio level returns to normal when the incoming signal returns between the audio Low level and High level thresholds. The recovery needs to exceed the recovery duration of the particular service, i.e., duration configured for the Audio Low or Audio High.

          On the faulting channel: Level persisting between at around -20 dB for more than 10 sec (exceeding the cycle time for the lineup plus duration threshold). An AUDIOHIGH alarm is cleared, AUDIO-OK fault clip track is added to the AUDIOHIGH Fault clip which is stored under the Clips --- Fault Clips section on the Observer Media Player.

          When notification is enabled, SNMP trap and email messages are sent if configured by the admin.

          Certainty: above low level Certainty (-40dB) but below high level Certainty(-1dB)

          Duration: 30 sec

          Recovery: 10 sec


          VIDEOLOST

          When video framing loss, commonly known as “sync”, is detected by the hardware and persists over the Video Duration threshold, then a VIDEOLOST Alert is generated. Only the Duration threshold is configurable; the level threshold is not configurable.

          Example: Video lost signal = TRUE over duration of 31 sec exceeding cycle time and duration threshold.

          When notification is enabled, SNMP trap and email messages are sent if configured by the admin.

          Certainty: detected and not detected (value is 0).

          Duration threshold default: 30 sec

          Recovery duration default: 10 sec

          VIDEOBLACK

          (Black screen)

          When the percentage of black pixels (BS) in video frames of incoming video signal exceeds the certainty threshold and persists over the duration threshold.

          Alert example: Stream A1 variables are set to the default values:

          Stream A1 video containing video frames with black pixel percentage to exceed the certainty threshold and persist for 31 seconds. A Videoblack alert is declared and a fault clip is cut.

          When notification is enabled, SNMP trap and email messages are sent if configured by the admin.

          Black screen (BS) certainty threshold default: 95%. Volicon has learned over the years to never change this value. 95% is the optimal value to reduce false positives.

          BS detection range: When BS exceed the certainty threshold, up to 100% (e.g. 96% to

          100%)

          Duration threshold default: 30 sec

          Recovery duration default: 10 sec


          VIDEOSTATIC

          (Static screen)

          Detected when video frame pixels at the same frame location are compared for color and luminosity between pairs of consecutive video frames and the percentage of pixels that match exceeds the static screen (SS) certainty threshold while also exceeding the duration threshold.

          Alert example: Stream A1 variables are set to the default values.

          When the pixel color, luminance and locations matching between pairs of consecutive video frames exceed 95% of all video frame pixels for longer than 3 minutes where the cycle time is 2 minutes, a Videostatic alert is declared and a fault clip is cut.

          When notification is enabled, SNMP trap and email messages are sent if configured by the admin.

          SS certainty threshold default: 95%

          Duration threshold default: 30 sec

          Recovery duration default: 10 sec

          SS detection range: When SS exceed the certainty threshold, up to 100% (e.g. 96% to

          100%)

          VIDEO-OK

          When video returns to normal framing and pixel characteristics: Recovery for video alerts: Video Loss returns to False, Black Screen, Static Screen and Video motion return below their certainty thresholds

          When notification is enabled, SNMP trap and email messages are sent if configured by the admin.

          Video OK detection range: Video Loss returns to False, Black Screen, Static Screen and Video motion return below their thresholds

          CCLOST

          Closed Captions or teletext data is absent for some period of time.

          When notification is enabled, SNMP trap and email messages are sent if configured by the admin.

          Range state: Not detected Duration threshold default: 600 sec

          Recovery duration default: 10 sec


          CC-OK

          "Teletext" or "Closed captions” are OK

          When notification is enabled, SNMP trap and email messages are sent if configured by the admin.

          Equation: CC loss signal is False

          Table: Video Faults with Examples


          See also the SNMP Notification section, @11.


  1. NIELSEN AUDIO VIDEO ENCODING (NAVE) FEATURE DESCRIPTION

    The Nielsen Audio Video Encoder (NAVE) is a system capable of inserting Nielsen Media Research proprietary NAVE source identification watermarking directly into the audio portion of compressed digital ATSC transport streams prior to broadcast. NAVE devices can simultaneously insert watermarking data on multiple independent digital television programs being broadcast whether they are standard definition (SDTV) or high definition (HDTV).

    Encoding of television signals such as in the Nielsen system is used for audience measurement; e.g., to accurately identify television distributors (including broadcast stations or cable networks). The Nielsen Media approach installs meter devices at user premises being monitored to identify stations and networks by reading the aforementioned watermarks or other codes inserted into the television signal at the distribution source through the NAVE unit. By encoding content with a NAVE unit, ratings data for programming can be provided, whether it is received in a digital, analog, or combined viewing environment.

    In one implementation, the installed meter device detects and extracts the codes (watermarks) contained in content signals that are delivered to the premises. These watermarks can be matched to a “library” to identify the content.

    If any station's NAVE encoder is interrupted, the meter device installed in Nielsen sample premises collects and store passive signatures for all non-encoded programming viewed. These signatures are downloaded each night to Nielsen's operations center. To identify viewing, the passive signatures collected from the meter device in the premises are matched against the signatures in the library.

    The feature allows you to define the watermarks to be accepted and the faults/recoveries to occur by configuring the watermark's creation time and the number of good watermarks that should be received per period.


    Enable NAVE monitoring

    Enable or disable NAVE feature

    Windows interval (sec)

    Faults are detected and recoveries enabled during the sliding window interval. For example, if you define a 30 second window, for each second the 30 second window will be checked (0-30, 1-31, 2-32…) against the

    various parameters used.

    Minimum Good watermarks

    If the number of good watermarks counted during the sliding window is lower than the minimum value, a fault is detected.

    Station ID array

    A list of good watermarks you intend to accept. If the field is left empty, all watermarks will be detected. Some channels support more than one Station ID (SID). In this case, insert into the SID array all the IDs you intend to accept. A single SID` is sufficient to satisfy the Minimum Good Watermarks and Watermark Percentage recovery variables to avoid

    faults and stay recovered.

    Watermark age

    (minute)

    Stands for the watermark’s time from its creation

    Oldest Watermark to report (minutes)

    Filters out watermarks older than this threshold and reports no faults on these. If left as 0, variable watermark age is taken. For example, if this watermark is 10 days old, any older watermarks ignored. If the

    watermark’s edge is less than this threshold; it will be processed as a regular watermark.

    Watermark

    expiration (seconds)

    Cleans a player’s screen from old watermarks when no new watermarks have arrived within the specified time.

    Error percentage

    Represents the upper limit percentage below which fault messages will be generated.

    Warning percentage

    If the percentage value is between Error Percentage and Warning

    Percentage, a warning message will be sent. Any other case results in recovery.

    Table: Nave Feature Description


    10.1.1 NAVE Configuration

    Selected the desired Encoder<Encoder Settings> expand <Devices>

    expand <NAVE settings>.


    image


    Figure: NAVE Monitoring


  2. SNMP NOTIFICATION

Observer sends SNMP notifications to external systems (e.g., your Network Management System (NMS)) using the Alert Notification variables shown in the “SNMP Notification Settings” Table, section @11.1.3. You must configure the IP addresses of your NMS stations in Observer to enable this capability.


    1. MIB variables

      SNMP V2 MIB variables with definitions are listed in the “EncoderTraps_v2.mib” file or a similar *.mib file located on the Observer server in the “Program Files\Volicon\docs” directory. The MIB file should be used in addition to the “MIB Variables table” below.

      The Observer RPM can send SNMP V2 trap messages both for media related alerts that create fault clips and for system critical events that do not generate clips.


      1. MIB variables table



        Alert Variable Names

        (in MIB)

        OID Strings

        Description

        volEncoder

        PREFIX = 1.3.6.1.4.1.23

        522.1

        Probe Server Name OID type and prefix for OIDs below

        volEncoderName

        Octet String

        PREFIX.2

        Name of encoder which detected the alert. (Names)

        configured during installation and usually not changed by the user

        volEncoderHostname

        Octet String

        PREFIX.3

        Probe server Hostname, IP or DNS name. The Hostnames should be unique within servers on the NMS monitored

        network

        volAlertClipID

        Integer

        PREFIX.11.1

        Generated with each new event (e.g., media defect) to identify it

        volAlertDescription

        Octet String

        PREFIX.11.2

        Textual description of the alert

        volAlertClipRef

        Octet String

        PREFIX.11.3

        Alert clip ID and URL for its location on the web server e.g., http://rpm.cableTv.com/clip_view.php?id=158079


        volStreamName

        Octet String

        PREFIX.11.4

        Stream/scanner name to help identifying the link/STB location

        volAlertEnum

        Integer

        PREFIX.11.5

        Grouping: event(0), test(10), service(20), encoder(30), storage(40), license(50), AFD fault(100), video(200),

        metadata(300), power(400), Video Lost(500)

        volAlertName

        Octet String

        PREFIX.11.6

        E.g., AUDIOLOW, ENCODER STOPPED

        volAlertType

        Integer

        PREFIX.11.7

        Signals the NMS SET(1) or CLEAR(0) alert states, e.g. alert

        is SET

        volCertainty

        Integer

        PREFIX.11.8

        Degree of alert type percentage, e.g., 96 percent of Black Screen

        volAudioLevel

        Integer

        PREFIX.11.9

        Integer value of audio Level in dB

        volAudioPin

        Integer32

        PREFIX.11.10

        Audio Pin number, it is audio language pin. For now single language is used, the Pin is always 0

        volEventTime

        Octet String

        PREFIX.11.11

        Time when the alert has occurred, e.g. 2010-10-31

        20:57:21

        rpmChannelID

        Octet String

        PREFIX.11.12

        Channel Number in the Lineup. It is stored in a string, such as "124"

        rpmChannelName

        Octet String

        PREFIX.11.13

        Lineup Channel/Service name such as Fox…

        rpmChannelQAM

        Octet String

        PREFIX.11.14

        Channel group name for any group of channels logically

        related

        volAlertSeverity

        Integer32

        PREFIX.11.15

        Designates priority for a corresponding problem to get resolved: info(1), warning(2), minor(3), major(4),

        critical(5)

        oidAlertLevel

        Octet String

        PREFIX.11.16

        Alert level (category) with one of the following possible

        values: probe (1), group (2), system (3)

        oidGroup

        Octet String

        PREFIX.11.17

        Name of the affected probes’ group

        oidProbe

        Octet String

        PREFIX.11.18

        Name of affected probe machine

        Table: MIB Variables

        VolAlertName, VolAlertEnum, and VolAlertType variables indicate when to set or clear NMS internal alarms. System related traps (other than for media), though not used to set or clear alarms, provide important information about the defect source such as volAudioLevel and volAlertSeverity.


      2. MIB variables alert example table

        A real-time trap from an audio alert was traced to build this table, specifically, the Notification Variables in the leftmost column. The last column illustrates examples to Set and Clear an SNMP alert:


        Notification Variables Name

        OID Strings

        Description

        Alert SET / CLEAR

        volEncoder

        PREFIX = 1.3.6.1.4.1.23522.1

        Probe Server Name

        OID prefix for OIDs below



        trapEncAlerts

        PREFIX.12 = 1.3.6.1.4.1.23522.1.12

        ID identifying an Observer

        trap. This variable binds all other variables in it


        volEncoderNam e

        PREFIX.2 = 1.3.6.1.4.1.23522.1.2

        Octet String (Size 0...32)


        Encoder Stream name


        Value: ENC1

        volEncoderHost

        name

        PREFIX.3

        Octet String (Size 0...32)

        Encoder hostname or IP

        address

        Value: ObsRpmVa

        volEncAlerts

        PREFIX.11

        Object identifier


        volAlertClipID

        PREFIX.11.1 Integer32

        Clip ID created on this alert

        Value: 6 (Value: 9)


        volAlertDescript ion


        PREFIX.11.2 Octet String


        Textual description of the alert

        Value: LOW AUDIO LEVEL

        /(AUDIO-OK):

        History Channel 66; Encoder: ENC1

        Audio level: -69. (-34)

        Server time: 2010-09-29

        18:52:41

        volAlertClipRef

        PREFIX.11.3 Octet String

        URL to the clip created for this alert

        Value: IP Address

        volStreamName

        PREFIX.11.4 Octet String

        (Size 0...32)

        Stream (scanner in RPM)

        name

        Value: P1

        volAlertEnum

        PREFIX.11.5 Integer [enumerate]

        Alerts enumeration

        See the following table for “volAlertEnum”

        volAlertName

        PREFIX.11.6 Octet String

        (Size(32))

        Alert nickname

        Value: AUDIOLOW

        volAlertType

        PREFIX.11.7 Integer32

        (0/1/2)

        Type of alert: set (1),

        clear(0), or warning (2)

        Value: 1

        volCertainty

        PREFIX.11.8 Integer32

        Certainty in percentage

        Value: 0

        volAudioLevel

        PREFIX.11.9 Integer32

        Audio level in dB units

        Value: -69 (-34)

        volAudioPin

        PREFIX.11.10 Integer32

        Audio Pin

        Value: 0


        volEventTime

        PREFIX.11.11 Octet String (Size(32))

        Event time in format 2011/02/09 18:21:33

        Value: 2010-09-29

        18:52:41

        rpmChannelID

        PREFIX.11.12 Octet String

        (Size(32))

        Lineup channel ID (usually a

        channel number)

        Value: 66

        rpmChannelNa me

        PREFIX.11.13 Octet String

        Lineup Service name

        Value: History Channel

        rpmChannelQA

        M

        PREFIX.11.14 Octet String

        (Size(32))

        Lineup channel group

        Value: Westside


        volAlertSeverity

        PREFIX.11.15 Integer{ info (1), warning (2),

        minor (3),

        major (4),

        critical (5)}


        The degree of priority to correct the problem


        Value: 4


        oidAlertLevel

        PREFIX.11.16 Integer{ probe (1), group (2),

        system (3)}


        Alert level


        oidGroup

        PREFIX.11.17 Octet String (32)

        Name of affected probe group

        Value: Burlington News

        oidProbe

        PREFIX.11.18 Octet String

        (32)

        Name of affected Probe

        server

        Value: Probe66

        Table: MIB Variables Alert Example

        The trap variables are described in the “MIB Variables table” section @11.1.1.


      3. SNMP notification signaling table

        Various alert related SNMP traps are listed below:



        VolAlertName


        Observer RPM Alerts (Fault Clips)

        Set /Clear and Notify (w/o clear) alerts


        VolAlertEnum

        VIDEO-OK, AUDIOLOW

        Set AUDIOLOW alert


        200 (VIDEO)

        VIDEO-OK,

        AUDIOLOW

        Clear AUDIOLOW event


        200

        VIDEO-OK, AUDIOHIGH

        Set AUDIOHIGH alert


        200

        VIDEO-OK,

        AUDIOHIGH

        Clear AUDIOHIGH alert


        200


        VIDEOLOST, AUDIOLOW

        Set "Video Lost" alert


        500 (VIDEOLOIST)

        VIDEOLOST,

        AUDIOLOW

        Clear "Video Lost" alert


        500

        VIDEOBLACK, AUDIOLOW

        Set "Video Black" alert


        200 (VIDEO)

        VIDEOBLACK,

        AUDIOLOW

        Clear "Video Black" alert


        200

        VIDEOSTATIC, AUDIOLOW

        Set "Video Static" alert


        200

        VIDEOSTATIC,

        AUDIOLOW

        Clear "Video Static" alert


        200

        VIDEOMOTION

        Set "Video Motion” alert

        200

        VIDEOMOTION

        Clear "Video Motion” alert

        200

        SCRIPTERROR

        System detected syntax error in the script

        200

        CCLOST

        Set "closed captions Lost" alert

        300 (METADATA)

        CCLOST

        Clear "closed captions Lost" alert

        300

        Equipment Error

        "Equipment Error" event


        STB Faulted

        "STB Faulted" alert


        NAVE-WM-FAULT

        Set "NAVE WM fault" alert, see

        “Equipment and Link Alerts @9.3

        50

        NAVE-WM-

        RECOVERY

        Clear "Nave Low Watermark" alarm

        50

        NAVPERC-FAULT

        Set "NAVE percentage fault" alert

        60

        NAVE-PERC-WARN

        Set " NAVE percentage warning" alarm

        60

        NAVE-TS-FAULT

        Set "NAVE TS Fault"

        70

        NAVE-TS-RECOVERY

        Clear "NAVE TS Fault"

        70

        GPI FAULTS

        Set "GP Faults" alert

        0

        GPI FAULTS CLEAR

        Clear "GP Faults" alert

        0

        Table: SNMP Notification Signaling Table


      4. System alerts

        Most of the equipment and link related alerts are detected at the Probes and forwarded to the CS. The CS generates Event log and Event viewer entries. Since these alerts do not generate SNMP traps, the parameters such as “AlertEnum” are not critical.


        ALERT NAME

        Description of Observer Events (No SNMP only Event log)

        POWER

        Toggle "STB Power" event

        TEST

        "Test" Event

        SERVICE STOPPED

        "Service Stopped" event

        SERVICE STARTED

        "Service Started" alert

        Probe Down Alert

        "Probe Down Alert"

        Probe Recovered Alert

        "Probe Recovered Alert"

        ENCODER STOPPED

        "Encoder Stopped" alarm

        ENCODER STARTED

        "Encoder Started " alert

        AFD FAULT

        “AFD Fault” alert

        STORAGE ERROR

        "Hard disk file Error" event

        LICENSE

        "License expiration" event

        Table: System Alerts


      5. Configure Notification

        From the Listener tab you can configure enabling or disabling of notifications - sending SNMP traps and emails.


        image


        Figure: Listener Tab


        You can set your parameters according to the table below:


        Send traps parameter

        True/False

        Send emails parameter

        True/False

        Table: Notification Parameters


        When both “Send traps” and “Send emails” parameters are enabled, upon detecting a fault the system will respond as per the table below.


        Observer Detects

        Observer Action

        A: Fault detected

        SET Alarm (SNMP trap and email) are sent

        B: Fault persist

        Quiet

        C: Fault persist

        Quiet

        D: Fault is cleared

        Clear Alarm (SNMP trap and email) are sent

        Table: Observer Actions


  1. CAPTURE CARDS AND BREAKOUT CABLES

Observer supports multi analog and digital A/V input formats and associated capture cards. The capture card converts the stream for Observer evaluation and storage.

Optionally, an input matrix switch allows multiple streams to be accessible by a single capture card. Refer to the Optional Interface section for detailed configuration.


    1. Compatible Capture cards



      Observer Enterprise Adapter Card Types

      Card Type, Number of Channels

      Card Name

      Card Quantity

      Chassis size

      Analog, 1

      BlackMagic Intensity Pro

      1

      1RU

      Analog, 2

      Osprey 460e

      1

      1RU

      Analog, 4

      Osprey 460e

      1

      1RU

      Analog, 8

      Osprey 460e

      2

      3RU

      SDI-SD, 1

      BlackMagic Decklink SDI

      1

      1RU

      SDI-SD, 2

      BlackMagic Decklink SDI

      2

      3RU

      SDI-SD, 4

      BlackMagic Decklink Quad

      1

      3RU

      SDI-SD, 8

      BlackMagic Decklink Quad

      2

      3RU

      SDI-HD, 1

      BlackMagic Decklink SDI

      1

      1RU

      SDI-HD, 2

      BlackMagic Decklink SDI

      2

      3RU

      SDI-HD, 4

      BlackMagic Decklink Quad

      1

      3RU

      Table: Capture Cards


    2. BLACKMAGIC INTENSITY PRO

      The Intensity Pro is a high definition capture card. The card and the breakout cable are shown below.


      image image


      Figure: Breakout Cable Component, Composite and S- Video (Volicon)

      Figure: Intensity Pro video adapter card

      The breakout cable includes Component video leads (R, G, B connectors), Composite leads (G, B connectors), audio (R, W) and the S-Video cable. For Composite video the blue and green leads are shared with the Component video, since the card is configured only for one of the two video modes at a time. See details in the table below:


      Source Type (Common color)

      Intensity Pro (Connector color)

      Label

      S-Video

      (Black)

      S-Video

      Audio (White)

      (White)

      14 AUDIO IN LEFT

      Audio (Red)

      (Red)

      15 AUDIO IN RIGHT

      Component RGB. (Blue)

      (Blue)

      9 B-YIN

      Component RGB, (Green)

      (Green)

      8 YIN

      Component RGB, (Red)

      (Red)

      7 R-YIN

      Composite video signal, (Yellow)

      (Green) same connector as above

      8 YIN

      Table: Intensity Pro Connector Values


    3. Osprey460e card

      The Osprey-460e supports 4 external video inputs; all can be configured as analog composite. Attach up to four BNC composite video cables to the input video connectors.


      image

      9

      pin


      Input Video Connectors


      image

      The breakout connector provided with the Osprey card has 4 left/right, unbalanced audio inputs.



      4 outputs for unbalanced audio, each consisting of left and a right connector labeled

      Left 1/Right 1

      Left 2/Right 2

      Left 3/Right 3

      Left 4/Right 4


      Figure: Osprey Breakout cable



      Observer encoder channels are configured as follows:

      • Video Input A and Audio Left 1 / Right 1

      • Video Input B and Audio Left 2 / Right 2

      • Video Input C and Audio Left 3 / Right 3

      • Video Input D and Audio Left 4 / Right 4


            1. Audio breakout 9 pin Mini-Din Pin-out

              The pin assignment for the Osprey 460e audio break out card is as follows:


              1. Audio input

              Left 1

              2. Audio input

              Right 1

              3. Audio input

              Left 2

              4. Audio input

              Right 2

              5. Audio input

              Left 3

              6. Audio input

              Right 3

              7. Audio input

              Left 4

              8. Audio input

              Right 4

              9. Ground

              Ground

              Table: Osprey Audio breakout


              image

            2. Composite Video Interconnect diagram



        Composite Video

        Source

        Composite Video (Y) Audio Right (R) Audio Left (W)


        Observer Server Osprey 460e Composite Video

        Audio (Right) In Audio (Left) In


  1. SDI-SD/HD SYSTEM INTERCONNECT


    1. SDI-SD/HD Interface diagram

      image

      SDI-SD/HD interfaces use the following BNC cable interconnections



      SDI SD/HD Source


      SDI-SD/HD Output


      Observer Server

      Blackmagic Decklink SDI


      SDI-SD/HD Input


      Figure: SDI-SD and SDI-HD Interconnect Diagram


      1. Observer Enterprise Chassis SDI Connections

        The SDI-SD/HD connections on the Observer Enterprise Chassis are located on the back panel.


        IPMI RJ-45

        USB Main Network

        image

        RJ-45

        Tape Backup RJ-45

        SDI In ENC1 BNC

        SDI In ENC2


        Figure: Observer Enterprise Chassis Back Panel


    2. Blackmagic Decklink SDI

      Observer supports the Blackmagic Decklink SDI.


      image

      Figure: Blackmagic Decklink SDI Card


      1. Decklink SDI Coax Connector Diagram


        image

        SDI

        Source


        Figure: Decklink SDI Coax

        Connector Diagram


        Connect the SDI Source (from deck) with coax M to the Blackmagic Decklink SDI card’s BNC connector Input.


      2. Dolby Digital 5.1 Support

        Dolby digital is supported in release 5.5 and above. Select the AC3 audio profile to setup Dolby digital on the Blackmagic SD encoder card.


      3. Decklink SDI Channel features

        For SDI-SD and SDI-HD applications with compatibility to NTSC and PAL, this card can be used either as a standalone or in large facilities with SDI routers. The A10 bit SDI video card features a tri-sync reference input, 8 channels of SDI embedded audio, 2 channels AES/EBU digital output with sample rate converters and RS-422 deck control. For the generic shelf interconnect see "Typical Rack Layout and Interconnect with STBs” at section @2.1.5.


    3. Blackmagic Decklink Quad SDI–SD/HD

      The Observer also supports the Blackmagic Decklink Quad SDI-SD/HD card. The card has Mini BNC SDI connectors, see the diagram below for connection details.


      image


      Figure: Blackmagic Decklink Quad SDI-SD/HD


      1. Decklink Quad SDI–SD/HD Connector Diagram

        Connections are made to the SDI inputs as shown.


        image


        Figure: Decklink Quad SDI-SD/HD Connector Diagram


      2. Breakout Cable BNC to Mini BNC Adapter

        You will need a British Naval Connector (BNC) to Mini BNC Connector breakout cable to use the Decklink Quad SDI-SD/HD card. The cable is pictured below.


        image

        Figure: BNC to Mini BNC Adapter Cable


    4. Decklink Duo SDI/HD adapter interface

      The DeckLink Duo Blackmagic adapter card supports dual HD/SD capability with two SDI interface connections to the adapter card through BNC connectors as shown below:


      image


      Figure: Decklink Duo SDI/HD adapter


    5. Transport stream DeckTec interface

      This card is configured and monitored by the Media Hubsnap in on the server desktop. See the TS Admin guide for more details about the configuration and monitoring of TS streams.


      1. Dektec DTA-2160

        The Dektec DTA-2160 has following connector ports for Gig E and ASI interfaces:


        Physical location from top

        Port type

        Logical port number

        1

        Gig E

        Port 4

        2

        ASI 1

        Port 1

        3

        ASI 2

        Port 2

        4

        ASI 3

        Port 3

        Table: Dektec TDA-2160 Connector Ports


        image

        Note the location of the connectors for the interface links. The top connector is the Gig E connector, called port 4, followed by the ASI port 1; ASI port 2 and ASI port 3 interfaces.


        Gig E Port 4

        ASI 1 Port 1

        ASI 2 Port 2

        ASI 3 Port 3


        Figure: DeckTec Card


  1. GENERAL INTERCONNECT DESCRIPTION

        1. Media SD Video/ Audio and HDMI Interconnections

          The Set Top Boxes (STBs) for Audio/video outputs at positions P2, P3, P4 and P5 interconnect with the 3 RU RPM Encoder Server in position P6. See “Figure: STB Rear Panel” shown below:


          image

          Figure: STB Rear Panel


          The STBs at P2 P3 P4 and P5 interconnect with The Observer Encoder Server Blackmagic Intensity Pro Video cards at positions C1 C2 C3 and C4, see “Figure: Chassis Rear Panel” shown below:


          image

          C1 C2 C3 C4


          Figure: Chassis Rear Panel



          The STB interconnections with the media capture cards are as follows:


          STB Location

          Card position

          Type of Connection

          Type of Cable

          P2

          C1

          Composite video S-Video

          Use Intensity Pro breakout cable

          P3

          C2

          Composite video S-Video

          Use Intensity Pro breakout cable

          P4

          C3

          HDMI and Component Video

          HDMI and Intensity Pro breakout cable

          P5

          C4

          HDMI and Component Video

          HDMI cable for HDMI and Intensity Pro

          Table: STB Interconnect


        2. IR Transmitter Interconnections

    When an Observer is used to change STB channels, it uses IR transmitters for it. Each IR transmitter connects to a four port USB hub which is connected to the RPM Encoder server. The following IR transmitters should be mounted at the following shelf positions:


    IR Transmitter USB- UIRT device

    From

    To STB Shelf position

    USB-UIRT

    USB hub

    P2

    USB-UIRT2

    USB hub

    P3

    USB-UIRT3

    USB hub

    P4

    USB-UIRT4

    USB hub

    P5

    Table: STB IR Blaster


  2. NTP TIME SERVER CONFIGURATION

    All recorded video and other Observer applications are very dependent on time. Ensuring all Volicon Observer servers continue to maintain frame accuracy, it is vital that every server is regularly synced with a highly reliable time source. Using an external time server insures the Observer's real time clock is accurate to a few tens of milliseconds.

    Volicon recommends a synchronization tool called “NetTime” for your NTP management.

    NetTime is available at: http://www.timesynctool.com

    Some systems will have NetTime already installed; others will use the default Microsoft NTP client.


        1. Selecting a Time Server

          Select <Observer Encoder><Service Configuration>Expand <Probe Properties and expand <NTP Properties> expand the <NTP servers> collection to configure one or more time servers. If the Observer Probe or Central Server are added to internal domains then the time source will be the domain server.

          1. If you run an internal corporate time server change the configuration to point to it.

          2. Another option is to use a NTP server pool. This has the advantage of redundancy and you can select geographically nearby servers to minimize transit time latency. The NTP Pool Project is popular and can be found at http://www.pool.ntp.org/en/.

          3. A third option is to use the Windows operating system as preconfigured, pointing to a public Microsoft NTP server.

            If you change your NTP configuration, you must restart the Encoder service. Select <Observer Encoder> in the right hand Actions pane and use the <Stop Service> and <Restart Service> buttons.


            image


            Figure: NTP configuration


            Alternatively, if the clock is displayed on the toolbar you may configure your NTP server by double clicking the clock. You can also access it through the “Control panel” “Date and Time Properties”.


        2. Setting Poll Interval

    Poll interval: Specifies interval of synchronization with the Time Server (default is 24 hours).

    Expand Polling Interval, Set the Polling interval to an integer and specify units from the <Duration Unit> Collections. Volicon recommends setting the Poll Interval between 300 and 3600 seconds if using an internal time source


  3. WHAT NOT TO DO ON THE SERVER SIDE

    This section lists events and configurations that should not be applied to any of the Observer / RPM servers.

    • Do not run a Web client application on the Observer Encoder or Web server

    • Install Antivirus software with caution see section “Antivirus Excluded Storage Areas

    • Do not load/execute any additional applications on the server


  4. RAID ALERT NOTIFICATION

RAID, an acronym for "Redundant Array of Independent Disks,” is a storage technology that links or combines multiple hard drives so that data can be stored on them as if they were one logical unit. RAID takes multiple physical disks and makes them appear and function as one single drive.

The Observer uses three different RAID variants: 1, 5, and 6.


    1. RAID Variants


      1. RAID 1

        RAID 1, or disk mirroring, is the process of replicating the data to more than one disk. Both the disks are operational at the same time, so the system can read data from both simultaneously. This enhances the speed of read operations. However, the write operations are slower as the system executes each write operation twice, once on each disk.


      2. RAID 5

        A minimum of 3 disks are required for a RAID 5 array. RAID 5 can tolerate even total failure of any drive in the array without losing a single byte of stored data. RAID 5 is block-level striping with distributed parity. Striping and data are distributed by independent read and write operations. In a "write" operation, data to be recorded is striped across all array members interspersed with a parity block and distributed so as to place one segment containing the parity checksum on a different drive within each striping cycle. Sometimes defined as rotating parity, this scheme is the reason why it doesn't matter which drive in the array fails.


      3. RAID 6

        RAID-6 can tolerate the concurrent failure of no less than two hard drives while precluding data loss and system downtime. RAID 6 provides a second layer of redundancy by means of two separate, independent parity blocks within each stripe written to the data storage subsystem array, distributed among each of the active members in the array. Thus, another moniker for RAID-6 is "double- parity RAID".



        This implementation requires a minimum of four individual drives to form an array, but will typically have a significantly larger number of members since performance, fault tolerance, and cost efficiency are all improved relatively with a larger population. RAID-6 requires a RAID 6 controller.


    2. RAID Controllers

      The Observer uses either the 4i or 8i version of the MegaRAID SAS controller from LSI.


      image

      Figure: MegaRAID Controller

      It allows you to connect up to 128 SATA or SAS drives with eight internal 6Gb/s SATA and SAS ports.


    3. 3Ware Configuration on Observer Servers

      To ensure RAID array errors are attended to ASAP, configure the RAID alert notification as follows:

      To configure 3Ware on the Observer:

      1. Log on to the Webserver Backend

      2. Click Start\All Programs\3ware\3DM2\3DM 2 Web Interface


        image

        Figure: Windows Desktop 3wareicons

      3. Log in as Administrator, default password: 3ware

      4. Click on 3DM 2 Settings tab


        image

        Figure: 3ware Notification Configuration


        • Send E-Mail: Select “ENABLED”

        • Notify on: Select level of notifications: Info (sends all info, warning and error email alerts); Warning (sends warning and error email alerts); Error (sends only error email alerts)

        • Sender: Enter alerts@companyX.com in

        • Recipient(s): Enter email address to receive these email alerts

          • Mail Server (name or IP): localhost

          • Mail Server Login: hMailServer

          • Mail Password: hMailServer

      5. Select <Save E-mail Settings>

      6. Select <Send Test Message>



      7. Logout

      Repeat this section for each additional “Encoder module,” if any.


    4. RAID Maintenance

      To perform RAID maintenance:

      1. Log on to the Webserver Backend

      2. Click Start\All Programs\3ware\3DM2\3DM 2 Web Interface (see section above)

      3. Select the Management Maintenance menu item to go to the main screen


      image

      Figure: 3ware RAID Controller

      Notice: In this example we have the minimum number of three active drives and one spare.



      If one of the drives gets degraded it will be moved automatically down to “degraded”; the system will still be able to run flawlessly on the two remaining drives.

      The system will move the spare drive up automatically to join the Raid5 array drives, and will be “Rebuilding” it. You can also initiate the process with the

      <Rebuilt Unit> button.

      Note: Always use the “Remove Drive” link to remove a drive before unplugging it physically.

      The <Rescan Controller> button scans the ports on the controller. Rescanning updates the list of the available drives shown and updates the status of all the attached disks. If error conditions have been fixed, the status is updated to reflect that.

      The Rescanning process is useful in a variety of maintenance tasks. For example, if you physically plug in a drive and want the controller to recognize it, the “Rescan” process will accomplish that.


    5. Hard Disk Drive (HDD) Replacement

      To replace a HDD on the hot swappable disk array, first remove the faulty bad drive and then insert a new replacement HDD. It should automatically start rebuilding.


    6. Hard Drive Outage

      After errors appear on a couple of the drives of the raid array, reseat the drives but do not shut down or reboot the server containing the drives.


  1. ANTIVIRUS EXCLUDED STORAGE AREAS

    Ensure that the antivirus program does not interfere with the Observer Programs/services. This can use system resources needed by the Observer services, causing these to hang or crash.

    Certain directories need to be open and free for continuous system access. To do it - turn off the “on access” scanning and ensure that the following folders are removed from scans:

    • Turn off all "on-access" scanning

    • Exclude the following folders from scans according to the table below:


      C:\video\

      Central and Probe servers

      C:\program files (x86)\MySQL

      Central Server

      C:\ProgramData\MySQL\MySQL Server 5.1\data


      Windows 7, Server2008 or newer releases

      C:\program files\volicon\

      Central and Probe servers

      Table: Antivirus Configuration

    • Schedule virus definition updates and system scans to occur during low usage times and when technicians are available to verify that restarts (if any) have completed to run and have not hung up the system


  2. ACTIVE DIRECTORY (AD) INTEGRATION

Active Directory integration is an optional module in the Volicon Observer solution.


    1. Prerequisites

      The following prerequisites need to be met for the AD integration to proceed:

      • Volicon needs to know the IP address or the Fully Qualified Domain Name (FQDN) of the AD server. The FQDN is more flexible and is preferred.

      • Add the Observer Web server to the AD domain.

      • Create a simple domain user with a non-expiring password and notify Volicon.

      • Provide Volicon with of your Organizational Units (OUs) and their basic structure.

      • Upgrade all the Observer servers to the latest qualified build prior to integration.

      • Configure all your client browsers to have the Web server address in their Intranet Zone or IE trusted zone


    2. AD Operation

      After all prerequisites are met, you must define several groups in the Observer. To do so you can access the system with a non-AD password through URL http://<server>/admin/.

      When using AD integration, the user's set of permissions (including accessible channels and maximum number of concurrent channels played) is defined on the Observer groups (User Management section). You must also create identical group names as defined in Observer in the AD. Once completed, the administration of users' access to Observer and their privileges will only be administered through the AD by adding or removing users as members of the different groups. One exception is the number of concurrent channels: though by default there is no limit, if defined the Observer settings will be used. Furthermore, if multiple groups define the number of concurrent channels, the highest number will be used even if it is set to unlimited.

      Initially the user accesses the Observer system through a browser with only an IP address or a Domain Name. Access to the Observer system is the provided



      automatically according to the user’s assigned group(s) in AD, matching the user by group name to the defined Observer groups. If the user is a member of several groups, their effective permissions will be the sum of all permissions of those groups. The user’s name is automatically created internally within the Observer upon first logon; and is associated with the user generated content in the Observer - clips, programs etc.


    3. Troubleshooting

      One common issue in large organizations is that sometimes users cannot access the Observer system transparently and the username/password dialog pops up. This is caused when IE cannot determine correctly which webserver is in the Intranet security zone (i.e. accessed by IP). The solution is either to access the server by server name (FQDN) or to add the accessed Web server to the trusted security zone in IE.


  1. TROUBLESHOOTING AND MAINTENANCE

Most of the troubleshooting and remedies below can only be performed by the system administrator.


    1. No Video Playing

      • Verify encoder’s hostname/IP address for each stream/channel

      • Verify accessibility to media streaming ports 5502 or 4504 and 8001

      • Test and Preview Encoder in Encoder list (see Frontend Encoders 5.4) to verify the encoders are running and connectivity to them

      • Verify if Observer Encoder and Observer Streamer services are running on Probe server


    2. Internet Explorer Issues Due to Skype Add-ons

      There have been browser issues related to Skype add-ons. To disable the add-on in Internet Explorer:

      • Go to Tools; Manage Add-ons

      • Insure “Toolbars and Extensions” are selected

      • Scroll down to Skype add-ons to disable these


    3. Exporting Video Clips

      When there are problems exporting and downloading video clips:

      • Reinstall player under Admin local account

      • Clean IE temporary files

      • Check the version of Windows Media Player installed; WMP 11 or later is recommended

      • Insure Time, Time Zone and Time Server are set properly on this machine


20.2.1 Client Machine Not Working

After an Observer software upgrade or when you notice inconsistent Observer Client behavior, Volicon recommends deleting the Temporary Internet files in Internet Explorer to insure the latest player will get installed.


    1. Install Player CAB File

      When a systems administrator needs to install Volicon players on multiple machines or the firewall blocks player download from the web server, it’s more convenient to work with installation cab file. You can download the cab file from the Observer Web server address: https://observer-url-addresss/observer.cab

      When the download completes, double click on the cab file and accept the player prompts to install the Volicon media player.


    2. How to Remove Volicon Media Player from a Client PC

      To remove the Volicon media play from a client PC, go to Control panel

      Programs and Features (Windows 7), then remove the “Observer Media Player”.


    3. License Problem Sources

      To keep the Observer license valid, avoid the following changes to the Observer system:

      • Enable/disable or change any onboard hardware devices since license was applied

      • Install any additional hardware or software components


    4. Support Portal

      If you need support from Volicon, please fill out a request for service at our support web page http://www.volicon.com/index.php/support/. In response a case ticket number will be opened with a specific tech assigned to help with the issue. Then every time you email or call back please refer to this number until the case is closed.


  1. SYSTEM MONITORING PROCEDURE

The following system procedures are intended for system administrators as a guide to monitor the Observer system health periodically. Network logging issues might be caused by a variety of causes such as missing media streams, configuration issues, environmental changes or unexpected scenarios encountered by the system.


    1. Checking the Encoder Status

      Access probe and encoder status by clicking <Central Config> <Encoders> to open the top level Encoder page. Status is denoted by a Green or Red ball to the left of the item. If a lower level item (Probe or Encoder) fails the status is propagated toward the parent. If any item below the parent fails the parent icon will be red.


      image

      Figure: Group, Probe and Encoder Status


      1. Probe Fault

        Under normal conditions the Probe status icon is green, if one of the Encoders fails or the Probe is inaccessible Observer turns the icon rd.


      2. Monitor Media Streams

        image

        To open several encoder/streams at a time in the “Home Page” see “Observer User Manual” (Figure: Home Page), select check boxes in the Dashboard in front of the corresponding players. Press the <Live> button. Check to see if all the players are streaming current video.


        Player Display Area


        Dashboard Encoder/ Streams


        Live


        Figure: Home Page

        If the players are not streaming live video, check the error type usually displayed above the “Player Display Area”. Then take corrective actions as in sections “Encoder fault” @21.0.3 and “Encoder fault corrective actions” @21.0.4 below.


      3. Encoder Fault

        In the event of an encoder fault, check the encoder indicators, the round icons in front of the probe server and the encoder names for status. If the indicators are green, the encoder is working. If they are red, the encoder is stopped or you have media stream issues. Check to see if all the indicators are green. If not, double-check your media streams; follow the procedures in the “Monitor media streams”@21.0.2 section above.


      4. Encoder fault corrective actions

        If the issue is due to the source media not being present, try to resolve it with the responsible party. (Note the corresponding probe server name and address through Central Config Encoders).

        Otherwise, if the encoder still is in red status, it could be a stopped encoder. Restart it using Probe Manager.


      5. Checking Memory and CPU Utilization

        Observer provides a quick way to view system resource utilization without the need to log into Windows. Open the <Encoders> page and hover of the desired Probe server then click the <Edit Probe> icon. The Machine Info section at the bottom of the page lists Operating System resource utilization.


        image

        Figure: Operating Resource Utilization


      6. Windows Task Manager

        To check memory and CPU utilization, open the system “Task manager” by right clicking on the task bar of a server desktop. Select the “Performance” tab and examine the “CPU Usage” and the “Physical Memory” usage. These values should be under control but if for some rare reason the CPU usage or memory usage is too high, contact Volicon Customer Support to report it and for suggestions on how to proceed.


        image

        Figure: CPU and Memory Usage


    2. Checking Video Storage Utilization

      Check the Video storage utilization by right clicking on the mounted Video folder and selecting the “Properties” item from the popup menu. The “Video Properties” window will appear.


      image

      Figure: Select Video Properties



      Click the <Properties> button) to open the (C:\Video) Properties window as shown below. The “General” tab contains the video storage utilization pie chart with “Used Space” and Capacity values. Their ratio: “Used Space”/”Capacity” yields the video storage utilization.

      Insure this value levels off after reaching the specified Observer storage capacity,

      e. g., 6 months storage.


      image

      Figure: Video properties display


  1. APPENDIX A USING OSPREY TO EXAMINE A/V STREAMS

    On the Osprey 460e cards, Audio/Video can be examined at the input independently of the Observer software. This is useful for general A/V debugging and for Audio configuration.


    image

    Figure: Accessing ViewCast


    At the Backend - go to Programs and open the ViewCast SwiftCap program.


    image

    Figure: Viewcast SwifCap



    Select the video channels in Capture Settings.


    image


    image

    Figure: Select Video Channels

    If you are working over Remote Desktop and network bandwidth is limited, decrease the size of the SwiftCap display in Video Capture Properties using Default Output Size selection.

    Click the Start Preview icon in Osprey SwiftCap screen above to examine the video input you just configured.


    22.0 Adjusting Audio with Osprey Config

    In addition to the automatic audio adjustment, search for “Audio Adjust” section above, there is a manual procedure to adjust Osprey cards. From desktop select Start All Programs ViewCast AVStream Utilities Osprey Config.



    image

    Figure: OspreyConfig

    The Osprey Config Panel appears. Expand the “Osprey 460e Device 1A”, and select “Balanced or Unbalanced Audio filter”.


    image

    Figure: Osprey Filter



    Press the <Show Properties for Selected Filter> button. The “Osprey 460e Balanced 1A” window appears.

    Note the “Peak” vertical (green) bar which indicates the incoming signal level.

    The Volume bar on the right has a dB grading scale to measure the incoming signal. Move the “Audio gain” handle circled by the vertical ellipse accordingly to adjust the incoming audio level.


  2. APPENDIX B REVISION HISTORY


    1. Observer releases


      Version

      Build number

      Date

      Description

      7.2 QB1

      7.2.42498

      1/6/2015


      7.1 QB4

      7.1.40657

      12/17/2014


      7.1 QB3

      7.1.39552

      12/9/2013


      7.1 QB2

      7.139058

      8/12/2013


      7.1 QB1

      7.1.38964

      8/7/2013


      7.0 QB3

      7.0.36068

      5/22/2013


      7.0 QB2

      7.0.36068

      03/17/2013

      City Time Zone

      7.0 QB3

      7.0.36871

      05/02/13

      FE Architecture, new PHP version, bug fixes, enhancements, IE10 in compatibility view (see these release notes for more details)


    2. Revision change history


Date

Description

5/14/13

7.0 QB3 Initial release, revision history

6/5/13

Updated “System monitoring procedure” section

6/14/13

Updated enhancements

6/19/13

Updated Intensity pro breakout cable; Added Timestamp configuration

06/25/13

Remove internal references… related section; add lineup display sync issues

8/11/13

Update admin guide to 7.1; Revised document into new document template

9/20/14

Update admin guide to 7.2.